6.4.6
Ground stacked LS18
Required items
-
M x pairs of LS rigging plates (LST-XBOW) for M x LS18 cabinets
-
1 x ground stack device (GPT-GSTK)
-
4 x M Quick release pins (VXT-BL820) for M cabinets
Ground stack device GPT-GSTK is rated for a maximum of 4 x LS18 provided this device is assembled
according to below rule:
-
Ground stack device GPT-GSTK must always be installed on a horizontal surface
Ensure that public is not allowed within a safety area which radius is equal or higher than assembly height.
It is highly recommended to secure the system to a fix point located at the back of the stack.
Procedure
-
Assemble the two connecting beam and the reinforcement beam with the handles
Depending on tilt angle – negative, null or positive - to be achieved, there are three positions to connect above assembly
-
to the supporting beams; below drawings detail these configurations:
PS SERIES HARDWARE SETUP PROCEDURE
IMPORTANT
System Manual PSR2 Series
Page 57 / 109