Ls18 And Ps15R2 Vertical Array Rigidly Mounted On A Ceiling - Nexo PSR2 Series System Manual

Table of Contents

Advertisement

6.3.7

LS18 and PS15R2 vertical array rigidly mounted on a ceiling

Required items
1 x GPI-BUMPER (allows +/-5° bumper tilt when installed below a flat surface; if higher bumper tilt is required, surface will
-
have to be defined accordingly)
M x LSI-CPLA counter-plates for M x LS18
-
1 x GPI-ANPL3 for the PS15R2
-
-
4 x 12mm diameter screws (not provided)
Ensure that the ceiling is strong enough to hold 4 times LS18 and PS15R2 cluster weight and that the four
screws 12mm diameter and corresponding plugs required to fix the bumper under the ceiling are properly
dimensioned.
Procedure
-
Set LS18s and PS15R2 sideways
-
Remove the TORX screws holding connector plates on upper side of LS18 and PS15R2
-
Remove the connector plates from LS18 and PS15R2
-
Remove the 4 locking screws from LS18 side wood panel (see figure below), these are no longer to be used
-
Apply Loctite 243 or equivalent to the screws that attach the LS18 connector plate to the cabinet, and reinstall the LS18
connector plates (see figure below left)
-
Position PS15R2 bottom counter-plates (see figure below left)
-
Position GPI-ANPL3 angle plate (set at 16°) and LSI-CPLA top counter-plates on LS18 upper sides according to figure
below right
-
Use thread lock coated screws (if not apply Loctite 243 or equivalent to shoulder screws) from LSI-CPLA and GPI-ANPL
kits