PROFET
+2 12V Arduino Shield
2 Board description
Figure 7
Application diagram with open load detection circuitry
Open load in OFF software flow principle:
IN = low; DEN = high;
activate pull-up(OLOFF = high);
read IS(A2 - P2.9/A3 - P2.10) ;
If IS = IIS(OLOFF)
deactivate pull-up(OLOFF = low);
read IS (A2 - P2.9/A3 - P2.10);
If IS = I
IS(OLOFF)
short-to-battery detected;
else open load detected;
else
if IS = I
IS(fault)
short-to-ground or overtemperature detected;
else
normal load condition detected;
deactivate pull-up (OLOFF = low);
end;