Samsung OfficeServ 7100 Technical Manual page 58

Hide thumbs Also See for OfficeServ 7100:
Table of Contents

Advertisement

OfficeServ 7100
TECHNICAL MANUAL
7.1.5 Connecting Cards to Ethernet
4SWM (P1~P4), MGI-16, and MP-10 (LAN port) cards can be connected to Ethernet by
using an Ethernet cable.
Pin No.
Function
7.1.6 Connecting to a Door Phone and a Door Lock
Connect a door phone and a door lock to the OfficeServ 7100 system by using a Door
Phone Interface Module (DPIM).
1) Connect a twisted pair of #24 AWG or #26 AWG wires to the LINE port of DPIM and
to P1 through P8 of 8DLI/16DLI2/8COMBO cards or 4DLM (mounted on UNI card
P1~P4) of the OfficeServ 7100 system.
CONNECTING TO THE 8DLI, 16DLI2, 8COMBO, 4DLM (mounted on
UNI Card)
Pin No.
1
Function
-
Figure 7.10 RJ-45 Digital Ports of the cards mentioned above (For Door Phone Connection)
1) Connect the Door Box port of the DPIM to the Line port of the door phone.
2) When using an automatic door lock, connect the Lock port of the DPIM and the
door phone contact point to the door lock.
3) The door lock contact point is designed to control low-voltage relay and uses 24 VDC
and 100 mA. Do not attempt to connect commercial AC power to these contact.
1
2
3
Tx+
Tx-
Rx+
Figure 7.9 RJ-45 EthernetPort
2
3
4
-
-
DLI TIP
7.6
Home Page
PART 7 APRIL 2007
RJ-45 port
4
5
6
-
-
Rx-
5
6
DLI RING
-
Table of Contents
INSTALLATION
7
8
-
-
7
8
-
-

Advertisement

Table of Contents
loading