For connecting with a Field Communicator, refer to
2.8.2
Trimming with digital zero trim button
Procedure
1. Set the transmitter pressure.
2. Remove the electronics housing cover.
3. Press and hold the Zero button for two seconds to perform a digital
zero trim.
4. Reinstall transmitter housing cover. Ensure a proper seal by installing
the electronics housing cover so that polymer contacts polymer (i.e.
no O-ring visible).
Figure 2-19: Digital Zero Button
Note
A zero trim can also be completed using AMS Wireless Configurator
once the device has joined the network.
2.9
Verify transmitter configuration
Operation can be verified in four locations:
At the device via the Local Display (LCD display).
By using the Field Communicator.
Via the Emerson Wireless Gateway's integrated web interface.
Via AMS Wireless Configurator.
2.9.1
Verify transmitter configuration using LCD display
The LCD display will show the output values at the same rate as the wireless
update rate. Refer to the Rosemount 3051 Wireless