Opening The Burner; Closing The Burner - Riello RL 70/E Installation, Use And Maintenance Instructions

Light oil burner
Table of Contents

Advertisement

6.3

Opening the burner

Disconnect the electrical supply from the burner by
means of the main system switch.
DANGER
Close the fuel interception tap.
DANGER
Wait for the components in contact with heat sourc-
es to cool down completely.
WARNING
➤ Loosen screws 1) and withdraw the cover 2);
➤ unscrew screws 3);
➤ fit the two extensions 4) supplied with a kit on request onto the
slide bars 5) (models with long blast tube).
➤ Pull part A)(Fig. 43) backward keeping it slightly raised to
avoid damaging the disk 6) on blast tube 7).
6.4

Closing the burner

Refit following the steps described but in reverse order; refit all
burner components as they were originally assembled.
Carry out all maintenance work and mount the cas-
ing again.
WARNING
After carrying out maintenance, cleaning or check-
ing operations, reassemble the hood and all the
safety and protection devices of the burner.
20045163
Maintenance
D1233
32
GB
Fig. 43