Technical Data - Emerson Daniel Senior Orifice Fitting Series Owner's And Operator's Manual

Table of Contents

Advertisement

Section 1: Introduction
January 2015
1.2.1

Technical data

Follow all the safety and equipment limits recommended in
It is the owner's and/or purchaser's responsibility to comply with these parameters.
PERSONAL PROTECTION HAZARD
Follow all parameters for the Senior Orifice Fitting indicated below.
Failure to do so may result in injury or equipment damage.
Product parameters and limitations:
Space limits:
See "Senior Orifice Fitting Technical Guide: DAN-DIF-TG"
Time parameters:
See Orifice Plate changing instructions
4
Fluid static pressure:
Fluid phases:
Fluids measured:
Fluid temperature parameters:
Orifice plate seal
material limitations:
w/ Nitrile Seal
w/ HNBR Seal
w/ FKM Seal
w/ FFKM Seal
Differential pressure:
Owner and operator manual
1.2.1 Technical data
Material of construction dependent. (Refer to ASME
codes and ANSI specifications when applicable)*
gas, liquid, vapor
most hydrocarbons
Material of construction dependent. (Refer to ASME
codes).*
Refer to ASME codes and ANSI specifications for
Fitting operating limits. Never exceed temperature
operating limits.
Maximum: 250 F (+121 C) Minimum: -30 F (-34 C)
Maximum: +300 F (+148 C) Minimum: -20 F (-28 C)
Maximum: +392 F (+200 C) Minimum: -15 F (-26 C)
Maximum: +620 F (+327 C) Minimum: -4 F (-20 C)
See AGA Report #3
3-9008-001 Rev M
of this manual.