Technical Data - Emerson CSI 6500 Quick Start Manual

Machinery health monitor, four channel analog i/o card
Hide thumbs Also See for CSI 6500:
Table of Contents

Advertisement

Available languages

Available languages

Product Information / Produktinformation A6620
Analog I/O Card
Fig. 2:
Analog input jumper
Installation
1. Check the slot wiring prior to installing the monitor.
2. Push the A6620 monitor into the prepared slot and press it with light pressure into the plug
connector.
3. Hand tighten the two anchoring screws on the front panel to secure the monitor
Any other information, e. g. shielding and grounding, configuration of the monitor, etc., can be
found in the direction for use "Analog I/O Card A6620", order number: 6110−90086.
1.6

Technical data

Only information with tolerances and limit values are considered as binding data. Data without
tolerances or error limits are provided as information only. We reserve the right to make technical
changes – particularly to the software.
All of the following information applies uniformly for channel 1 and channel 2, if not otherwise
specified.
1.6.1 Signal conditioning
Measured value inputs
Differential voltage amplification inputs, non−reactive, open−circuit and short−circuit proof.
Channel 1
Channel 2
Channel 3
Channel 4
Input nominal range
Limit range
Input resistance
1
2
3
4
Chan.
JP1
a)
IN1+: d06 / IN1−: z06 / IN1 COM: b06
IN2+: d08 / IN2−: z08 / IN1 COM: b08
IN3+: d10 / IN3−: z10 / IN1 COM: b10
IN4+: d12 / IN4−: z12 / IN1 COM: b12
−10 V ... +10 V DC
−15 V ... +15 V DC
> 10 MΩ
50 Ω / 0,1W Shunt switch on for current measurment
0/4 ... 20 mA
Chan.
1
2
3
4
JP1
b)
Page 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A6620

Table of Contents