Download Print this page

Christie CP2210 Technical Bulletin page 5

Replacing the icp battery
Hide thumbs Also See for CP2210:

Advertisement

Reset the ICP real-time clock
1. Download and install the ICP and Enigma Control Program on a computer that you can connect
to the projector.
2. Connect one end of an Ethernet cable to the Ethernet port on the computer with the ICP and
Enigma Control Program.
3. Connect the other end of the Ethernet cable to the Ethernet port on the projector.
4. Click Start > All Programs > ICP and Enigma Control Program.
5. On the Connection tab, select External Ethernet Port.
6. In the Ethernet Configuration area, enter the projector IP address in the IP Addr field and
press Select.
7. In the Login area, click Login.
8. Complete the User ID and Password fields and click OK.
9. Click OK.
10. Click the Sys-Config tab.
11. Click RTC Time.
12. In the Set Time area, select PC Time (UTC) and click Set RTC Time.
13. Close the ICP and Enigma Control Program.
Restore projector settings and information
This procedure is optional. Complete this procedure if an error has occurred and you need to
recover projector settings and other data.
1. Log on to the projector with service permissions.
2. Insert the USB flash drive with the backup into the USB port on the side of the projector.
3. Tap Menu > Service Setup > File Management.
4. Tap Browse to the right of the File to restore field.
5. Select the location of the upgrade file in the Drive Letter list.
6. Browse to the location of the upgrade file in the Folder list.
7. Tap the upgrade file and then tap Open.
8. Select the type of file to restore in the Select type list.
9. Tap Restore.
10. Tap Yes.
Replacing the ICP Battery Technical Bulletin
020-200313-01 Rev. 1 (02-2015)
5

Advertisement

loading

This manual is also suitable for:

Cp2215Cp2220Cp2230Cp4220Cp4230Solaria one ... Show all