2.2.5
COM Connector
UNO-137 has 2 COM RS232/422/485 ports of terminal block type. They offer trans-
mission speeds of 50 ~115.2 kbps.
The default mode for both COM ports (COM1&COM2 )is RS-232 Mode. Settings can
be adjusted via an on-board switch (SW1).
(Please refer to User Manual- Appendix A.8 for RS232/422/485 settings).
Table 2.2: COM Connector Pin Assignments
Pin
1
3
5
7
9
UNO-137 User Manual
COM1 Mode
Signal Name Pin
RS232
CTS
RS422
T-
RS485
D-
RS232
RXD
RS422
T+
RS485
D+
RS232
TXD
RS422
R+
RS485
RS232
RTS
RS422
R-
RS485
RS232
GND
RS422
GND
RS485
GND
COM2 Mode
RS232
2
RS422
RS485
RS232
4
RS422
RS485
RS232
6
RS422
RS485
RS232
8
RS422
RS485
RS232
10
RS422
RS485
12
Signal Name
CTS
T-
D-
RXD
T+
D+
TXD
R+
RTS
R-
GND
GND
GND