Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual page 7

Indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

28MZ – IDT Steam
Coil Position
H – Horizontal
V – Vertical
Rows
1 – 1 Row
2 – 2 Row
Tubes In Face*
If position 11 = S
1 in.
39M Unit
Size
L
M
B
S
03W
8
5
5
N/A
06W
8
6
5
5
07T
13
11
8
7
08W
9
6
5
5
09T
14
12
10
8
10W
9
6
5
5
11T
16
14
10
9
12T
17
14
11
9
12W
11
9
8
5
14W
11
10
8
5
16T
20
16
13
10
17W
12
10
9
6
18T
21
17
13
11
21W
15
13
11
7
22T
22
18
14
12
25T
12/12
20
16
13
25W
15
13
11
7
30T
12/12
20
16
13
30W
15
13
11
7
35T
12/13
21
17
14
36W
18
15
12
10
37T
15/15 13/13
20
16
40W
10/10
18
15
10
42T
15/15 13/13 10/10
16
50W
11/12
18
15
11
51T
15/15 13/13 10/10
15
58T
17/17 14/15 11/11
18
61W
14/14 11/12
18
14
72W
16/16 13/13 10/11 N/A
85W
16/16 13/13 10/11 N/A
96W
18/18 14/15 12/12 N/A
110W 18/18 14/15 12/12 N/A
Fin Material
Fins Per Inch
Casing Material
B – AL
6
GALV.
E – AL
9
GALV.
C – AL 12 GALV.
H – AL
6
ST. STL.
L – AL
9
ST. STL.
J – AL 12 ST. STL.
P – CU 6
ST. STL.
S – CU 9
ST. STL.
Q – CU 12 ST. STL.
LEGEND
B
— Bypass
L
— Large
M
— Medium
S
— Small
*Multiple values indicated that two coils must be ordered.
†Distance between tube sheets.
28MZ H 1 26 F B T 074 A X N –
If position 11 = T
5/8 in.
L
M
B
S
16
10
10
N/A
16
12
10
10
26
22
16
14
18
12
11
10
28
24
20
16
18
12
11
10
32
28
20
18
34
28
22
18
22
18
16
10
22
20
16
10
40
32
26
20
24
20
19
12
42
34
26
22
30
26
22
14
44
36
28
24
24/24
40
32
26
30
26
22
14
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
N/A
N/A N/A N/A
Fig. 5 — 28MZ (Steam Coil) Nomenclature
– – Coil Revision
Coating
N – Non-Coated
E – E-Coated
X – Always
Header Style
A – MPT Std
Header Note:
Pos. 11 (Type S )
Supply = 2 1/2 in. MPT
Condensate = 2 1/2 in. MPT
Pos. 11 (Type T )
(1) Row 10-28TF = 2 in. MPT (Supply and Return)
29-40
(2) Row 10-28TF = 2 1/2 in. MPT (Supply and Return)
29-40TF = 3 in. MPT (Supply)
TF-Tubes in face
39M Unit
Size
03W
06W
07T
08W
09T
10W
11T
12T
12W
14W
16T
17W
18T
21W
22T
25T
25W
30T
30W
35T
36W
37T
40W
42T
50W
51T
58T
61W
72W
85W
96W
110W
Tube Size and Copper Wall
S – 1 in. O.D. x .030 Wall Outer Tube
5/8 in. O.D. x .020 Wall Inner Tube
T – 5/8 in. O.D. x .035 Wall Outer Tube
3/8 in. O.D. x .020 Wall Inner Tube
7
= 2 1/2 in. MPT (Supply)
2 in. MPT (Return)
= 2 1/2 in. MPT (Return)
DBTS† (in.)
20
34
26
40
29
52
32
35
52
59
38
65
41
65
47
49
74
59
92
67
96
59
96
67
104
81
81
104
107
126
126
144

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aero 39mw series