39M UNIT SIZE
CIRCUITING TYPE
Airflow (cfm) at 500 fpm
Total Face Area (sq ft)
Tubes in Face
Tube Length (in.)
104
No. of Circuits - Total
4-Row Coil
Upper
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
1-5/8
Distributor Connections (in. OD)
1-3/8
Distributor Nozzle Size
C-15
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
1-5/8
Distributor Connections (in. OD)
1-3/8
Distributor Nozzle Size
C-15
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
6-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
1-5/8
Distributor Connections (in. OD)
1-3/8
Distributor Nozzle Size
C-15
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
1-5/8
Distributor Connections (in. OD)
1-3/8
Distributor Nozzle Size
C-15
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
8-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
1-5/8
Distributor Connections (in. OD)
1-3/8
Distributor Nozzle Size
C-15
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
1-5/8
Distributor Connections (in. OD)
1-3/8
Distributor Nozzle Size
C-15
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
LEGEND
TXV — Thermostatic Expansion Valve (Field Supplied)
*When 2 nozzle sizes are listed, the smaller nozzle should be located on the upper distributor.
Table 11 — Direct-Expansion Circuiting Data (cont)
Medium Face Area Coils (cont)
61W
Full
Double
Full
25,278
50.6
28
28
28
28
32
32
104
104
104
107
107
28
28
56
56
32
32
Lower
Upper
Lower
Upper
Lower
2
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-15
C-17
C-17
2
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-15
C-17
C-17
2
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-15
C-17
C-17
2
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-15
C-17
C-17
2
2
4
4
2
2
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-15
C-15
C-15
C-17
C-17
2
2
4
4
2
2
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-15
C-15
C-15
C-17
C-17
72W
85W
Double
Full
Double
29,722
35,000
59.4
70.0
32
32
32
32
32
107
107
126
126
126
64
64
32
32
64
Upper
Lower
Upper
Lower
Upper
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-17
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-17
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-17
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-17
4
4
2
2
4
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
C-17
C-17
4
4
2
2
4
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
C-17
C-17
NOTE: Factory-supplied distributors have factory-selected nozzle sizes as shown. If necessary,
replace factory-supplied nozzles with field-supplied and field-installed nozzles. Consult
AHUBuilder
®
software selection program for correct nozzle selection.
46
96W
Full
Double
39,375
78.8
32
36
36
36
36
126
126
126
126
126
64
36
36
72
72
Lower
Upper
Lower
Upper
Lower
Upper
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
4
2
2
4
4
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
C-17
C-17
C-17
4
2
2
4
4
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
C-17
C-17
C-17
110W
Full
Double
45,000
90.0
36
36
36
36
144
144
144
144
36
36
72
72
Lower
Upper
Lower
2
2
1-5/8
1-3/8
C-17
2
2
1-5/8
1-3/8
C-17
2
2
1-5/8
1-3/8
C-17
2
2
1-5/8
1-3/8
C-17
2
2
4
4
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
2
2
4
4
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aero 39mw series

Table of Contents