Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual page 143

Indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

39M
ABB PART
MOTOR HP
NO. ACH550-UH-
1
/
04A6-2
2
3
/
04A6-2
4
1
04A6-2
1
/
06A6-2
1
2
2
07A5-2
3
012A-2
5
017A-2
7
/
1
024A-2
2
10
031A-2
15
046A-2
20
059A-2
25
075A-2
30
088A-2
40
114A-2
50
143A-2
60
178A-2
75
221A-2
1
/
03A3-4
2
3
/
03A3-4
4
1
03A3-4
1
1
/
03A3-4
2
2
03A3-4
3
06A9-4
5
06A9-4
7
1
/
012A-4
2
10
015A-4
15
023A-4
20
031A-4
25
031A-4
30
038A-4
40
059A-4
50
072A-4
60
078A-4
75
097A-4
100
125A-4
125
157A-4
150
180A-4
1
04A6-2
1
1
/
06A6-2
2
2
07A5-2
3
012A-2
5
017A-2
7
1
/
024A-2
2
10
031A-2
15
046A-2
20
059A-2
25
075A-2
30
088A-2
40
114A-2
50
143A-2
60
178A-2
75
221A-2
1
03A3-4
1
/
03A3-4
1
2
2
04A1-4
3
06A9-4
5
08A8-4
7
/
1
012A-4
2
10
015A-4
15
023A-4
20
031A-4
25
038A-4
30
045A-4
40
059A-4
50
078A-4
60
097A-4
75
125A-4
100
157A-4
125
180A-4
LEGEND
MCCB — Molded-Case Circuit Breaker
NOTE: Two-pole motors operate at a nominal 3600 rpm for 60 Hz and 3000 rpm for 50 Hz;
4-pole motors operate at a nominal 1800 rpm for 60 Hz and 1500 rpm for 50 Hz.
Table 37 — VFD Data
MAX. CONTINUOUS
FUSE AMPS
OUTPUT AMPS
208-230 VOLT / 3 PHASE / 60 HZ (PROGRAMMED TO OPERATE AT 208 VOLTS)
4.6
4.6
4.6
6.6
7.5
11.8
16.7
24.2
30.8
46.2
59.4
74.8
88.0
114.0
208-230 VOLT / 3 PHASE / 60 HZ (PROGRAMMED TO OPERATE AT 230 VOLTS)
143.0
178.0
221.0
460 VOLT / 3 PHASE / 60 HZ (PROGRAMMED TO OPERATE AT 460 VOLTS)
3.3
3.3
3.3
3.3
3.3
5.4
6.9
11.9
15.4
23.0
31.0
31.0
38.0
59.0
72.0
77.0
96.0
124.0
157.0
180.0
200-230 VOLT / 3 PHASE / 50 HZ (PROGRAMMED TO OPERATE AT 200 VOLTS)
4.6
6.6
7.5
11.8
16.7
24.2
30.8
46.2
59.4
74.8
88.0
114.0
143.0
178.0
221.0
380 VOLTS / 3 PHASE / 50 HZ (PROGRAMMED TO OPERATE AT 400 VOLTS)
3.3
3.3
4.1
5.4
8.8
11.9
15.4
23.0
31.0
38.0
44.0
59.0
77.0
96.0
124.0
157.0
180.0
MCCB
RATED AMPS
10
15
10
15
10
15
10
15
10
15
15
15
25
25
30
30
40
40
60
60
80
80
100
100
110
110
150
150
200
200
250
250
300
300
10
15
10
15
10
15
10
15
10
15
10
15
10
15
15
15
20
20
30
30
40
40
40
40
50
50
80
80
90
90
100
100
125
125
175
175
200
200
250
250
10
15
10
15
10
15
15
15
25
25
30
30
40
40
60
60
80
80
100
100
110
110
150
150
200
200
250
250
300
300
10
15
10
15
10
15
10
15
15
15
15
15
20
20
30
30
40
40
50
50
60
60
80
80
100
100
125
125
175
175
200
200
200
250
143
PROGRAMMED SETTINGS
OVERLOAD TRIP AMPS
MAX. OUTPUT AMPS
4 POLE / 2 POLE
4 POLE / 2 POLE
1.8/
1.7
2.6/
2.5
3.5/
3.2
5.2/
4.2
6.7/
5.9
9.0/
8.5
14.5/ 13.6
21.4/ 20.7
27.4/ 27.4
40.5/ 40.5
53.0/ 52.2
67.0/ 66.0
82.0/ 78.0
92.0/107.0
114.0/110.0
125.0/130.0
142.0/130.0
154.0/135.0
172.0/145.0
186.0/166.0
221.0/172.0
0.9/
1.0
1.3/
1.2
1.6/
1.5
2.2/
2.0
2.7/
2.7
4.0/
3.8
6.2/
6.0
9.0/
8.8
12.0/ 11.6
17.6/ 16.5
23.0/ 23.0
29.0/ 28.0
34.5/ 34.0
46.0/ 44.0
58.0/ 55.0
73.0/ 68.0
90.0/ 85.0
118.0/110.0
124.0/114.0
141.0/139.0
147.0/147.0
171.0/171.0
177.0/177.0
3.3/
3.3
4.9/
4.9
6.3/
6.3
8.7/
8.7
14.0/ 14.0
21.2/ 20.2
27.2/ 27.4
41.4/ 40.5
53.4/ 49.0
65.4/ 66.0
78.0/ 78.0
107.0/107.0
135.0/135.0
169.0/169.0
210.0/210.0
210.0/210.0
1.7/
1.7
2.5/
2.5
3.2/
3.2
4.5/
4.5
7.0/
7.0
10.6/
8.9
13.6/ 11.6
20.7/ 17.0
26.7/ 24.5
32.7/ 29.5
39.0/ 39.0
53.5/ 45.5
67.5/ 67.5
84.5/ 84.5
105.0/105.0
105.0/105.0
134.0/134.0
134.0/134.0
134.0/134.0
3.0/
2.2
3.2/
3.0
3.8/
3.8
5.8/
5.8
7.2/
7.0
10.0/
9.5
16.7/ 16.0
24.0/ 23.0
30.8/ 30.0
46.2/ 43.0
59.4/ 57.0
74.0/ 71.0
85.0/ 82.0
1.5/
1.2
1.7/
1.5
1.9/
1.7
2.8/
2.3
3.0/
3.0
4.5/
4.2
6.9/
6.5
10.0/
9.5
13.6/ 12.8
19.3/ 19.0
25.0/ 25.0
31.0/ 30.0
38.0/ 38.0
48.0/ 50.0
60.0/ 60.0
77.0/ 72.0
94.0/ 90.0
3.9/
3.9
5.8/
5.8
7.1/
7.1
10.0/ 10.0
16.7/ 16.7
24.2/ 24.2
30.8/ 30.8
46.2/ 46.2
59.4/ 56.0
74.0/ 74.8
86.0/ 86.0
114.0/114.0
135.0/135.0
169.0/169.0
2.3/
2.3
3.3/
3.3
3.8/
3.6
5.4/
5.3
8.5/
8.0
11.9/ 11.0
15.4/ 14.6
22.6/ 21.0
29.3/ 29.0
37.0/ 36.0
44.0/ 44.0
57.0/ 55.0
70.0/ 70.0
88.0/ 88.0
134.0/134.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aero 39mw series

Table of Contents