Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual page 50

Indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

39M UNIT SIZE
CIRCUITING TYPE
Airflow (cfm) at 500 fpm
Total Face Area (sq ft)
Tubes in Face
Tube Length (in.)
No. of Circuits - Total
4-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
6-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
8-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
LEGEND
TXV — Thermostatic Expansion Valve (Field Supplied)
*When 2 nozzle sizes are listed, the smaller nozzle should be located on the upper distributor.
Table 11 — Direct-Expansion Circuiting Data (cont)
Large Face Area Coils (cont)
18T
Half
Full
Double
8,898
17.8
24
26
24
26
24
41
41
41
41
41
12
13
24
26
48
Upper
Lower
Upper
Lower
Upper
2
2
2
2
1-1/8
1-1/8
1-3/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-4
G-6/G-4
C-12
C-12
2
2
2
2
1-1/8
1-1/8
1-3/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-4
G-6/G-4
C-12
C-12
2
2
2
2
1-1/8
1-1/8
1-3/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-4
G-6/G-4
C-12
C-12
2
2
2
2
1-1/8
1-1/8
1-3/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-4
G-6/G-4
C-12
C-12
2
2
2
2
4
1-1/8
1-1/8
1-3/8
1-5/8
1-3/8
7/8
7/8
1-3/8
1-3/8
1-3/8
G-4
G-6/G-4
C-12
C-12
C-12
2
2
2
2
4
1-1/8
1-1/8
1-3/8
1-5/8
1-3/8
7/8
7/8
1-3/8
1-3/8
1-3/8
G-4
G-6/G-4
C-12
C-12
C-12
21W
Half
Full
Double
Half
10,720
21.4
26
38
38
38
26
41
65
65
65
47
52
19
38
76
13
Lower
Upper
2
2
2
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
7/8
E-10/E-8 C-20
G-6/G-4
2
2
2
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
7/8
E-10/E-8 C-20
G-6/G-4
2
2
2
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
7/8
E-10/E-8 C-20
G-6/G-4
2
2
2
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
7/8
E-10/E-8 C-20
G-6/G-4
4
2
2
4
2
1-5/8
1-3/8
1-5/8
1-5/8
1-1/8
1-3/8
1-1/8
1-3/8
1-3/8
7/8
C-12 E-10/E-8 C-20
C-20
G-6/G-4
4
2
2
4
2
1-5/8
1-3/8
1-5/8
1-5/8
1-1/8
1-3/8
1-1/8
1-3/8
1-3/8
7/8
C-12 E-10/E-8 C-20
C-20
G-6/G-4
NOTE: Factory-supplied distributors have factory-selected nozzle sizes as shown. If necessary,
replace factory-supplied nozzles with field-supplied and installed nozzles. Consult
AHUBuilder
®
software selection program for correct nozzle selection.
50
22T
Full
Double
11,016
22.0
28
26
28
26
28
47
47
47
47
47
14
26
28
52
56
Lower
Upper
Lower
Upper
Lower
2
2
2
1-1/8
1-5/8
1-5/8
7/8
1-3/8
1-3/8
G-6
C-12
C-15
E-10/E-8 C-20
2
2
2
1-1/8
1-5/8
1-5/8
7/8
1-3/8
1-3/8
G-6
C-12
C-15
E-10/E-8 C-20
2
2
2
1-1/8
1-5/8
1-5/8
7/8
1-3/8
1-3/8
G-6
C-12
C-15
E-10/E-8 C-20
2
2
2
1-1/8
1-5/8
1-5/8
7/8
1-3/8
1-3/8
G-6
C-12
C-15
E-10/E-8 C-20
2
2
2
4
4
1-1/8
1-5/8
1-5/8
1-5/8
1-5/8
7/8
1-3/8
1-3/8
1-3/8
1-3/8
G-6
C-12
C-15
C-12
C-15 E-10/E-8 C-20
2
2
2
4
4
1-1/8
1-5/8
1-5/8
1-5/8
1-5/8
7/8
1-3/8
1-3/8
1-3/8
1-3/8
G-6
C-12
C-15
C-12
C-15 E-10/E-8 C-20
25W
Half
Full
Double
12,205
24.4
38
38
38
72
72
72
19
38
76
2
2
1-3/8
1-5/8
1-1/8
1-3/8
2
2
1-3/8
1-5/8
1-1/8
1-3/8
2
2
1-3/8
1-5/8
1-1/8
1-3/8
2
2
1-3/8
1-5/8
1-1/8
1-3/8
2
2
4
1-3/8
1-5/8
1-5/8
1-1/8
1-3/8
1-3/8
C-20
2
2
4
1-3/8
1-5/8
1-5/8
1-1/8
1-3/8
1-3/8
C-20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aero 39mw series

Table of Contents