3-11. CHANGING THE
FILTER ENVELOPE
(Continued)
3-24
11. Slide the screens into a clean filter envelope.
12. Fold the corners in and then double fold the open end.
13. Clamp the envelope in place with the two filter retaining clips.
Step 12
14. Replace the crumb catcher screen on top of the filter paper.
Screw on the suction standpipe assembly.
15. Place complete filter screen assembly back into filter drain pan
and slide pan back into place beneath the fryer.
16. Connect the filter union by hand. Do not use a wrench to tighten.
17. Slide the condensation drain pan back into place. The fryer is
now ready to operate.