MENU CODE 6 1 – POS TYPE
Menu Code 61 is used to determine the processing type used for POS systems. If the POS has custom handling implemented in the
dispenser's POS-Dispenser interface then the POS type will be set to that POS otherwise it is left to the standard default.
only needs to be set if the POS is using Retalix and the CNG is configured as a 1-Sided 2-Hose dispenser.
0 – (Default) Standard
1 – Retalix
TO SELECT A DIFFERENT O PTION IN MENU CODE 61, FOLLOW THIS PROCED URE:
1.
Press the number 6 and 1, then the [MODE] button on the keypad. The PPM display
shows the dispenser is in Menu Code 61. If the dispenser has not been programmed
since it came from the factory, the number 0 appears in the main display. This is the
default setting as shown in Figure 4.59.
2.
To change the setting, use 0 or 1 button on the keypad to enter a new option. Note:
If an error is made, press the correct number. The new number will replace the error.
3.
When the correct option number appears in the main display, press the [ENTER]
button to save the selection.
4.
Press the [CANCEL] button to exit this Menu Code.
MENU CODE 6 3 – HANDLE MASKING
Menu Code 63 is used to enable or disable handle masking. If a POS will not authorize a dispenser with an active handle this mode will
need to be set to 1. If this mode is set to zero the dispenser will report an activated handle immediately.
0 – (Default) Disable Handle Masking
1 – Enable Handle Masking
TO SELECT A DIFFERENT O PTION IN MENU CODE 63, FOLLOW THIS PROCED URE:
1.
Press the number 6 and 3, then the [MODE] button on the keypad. The PPM display
shows the dispenser is in Menu Code 61. If the dispenser has not been programmed
since it came from the factory, the number 0 appears in the main display. This is the
default setting as shown in Figure 4.60.
2.
To change the setting, use 0 or 1 button on the keypad to enter a new option. Note:
If an error is made, press the correct number. The new number will replace the error.
3.
When the correct option number appears in the main display, press the [ENTER]
button to save the selection.
4.
Press the [CANCEL] button to exit this Menu Code.
MENU CODE 65 – MAXIMUM FILL PRESSURE
Menu Code 65 is used to program the maximum fill pressure. The maximum fill pressure (UPT) is the upper limit of the target pressure for
a fill. The default for the pressure limit for the station are based on the grade type (target pressure) assigned in menu code 07. Default
pressure is (P36) 4000 PSI.
TO SELECT A DIFFERENT O PTION IN MENU CODE 65, FOLLOW THIS PROCED URE:
1.
Press the number 6 and 5, then the [MODE] button on the keypad. The PPM display
shows the dispenser is in Menu Code 65 as shown in Figure 4.61. If the dispenser has
not been programmed since it came from the factory, the grade type configured in
menu code 7 appears in the main display. This is the default setting.
2.
To change the setting, use 0 or 1 button on the keypad to enter a new option. Note:
If an error is made, press the correct number. The new number will replace the error.
3.
When the correct option number appears in the main display, press the [ENTER]
button to save the selection.
4.
Press the [CANCEL] button to exit this Menu Code.
36
Programming
Note: This mode
Sale $
postyp
GGE
code
- 61
FIGURE 4.59 – POS TYPE
Sale $
Handle ind
GGE
code
- 63
FIGURE 4.60 – Handle Masking
Sale $
GGE
code
- 65
FIGURE 4.61 – MAX FILL PRESSURE
std
0
upt

Advertisement

Table of Contents