Regency City ACV40E Series Owners & Installation Manual page 51

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

City Series 40 ACB40E
OPTIONAL FAN KIT INSTALLATION
NOTE: Installation of Fan Kit should be done prior
to installation of the wall.
2) Mount and secure the fan housing assembly to
framing members, the front of the fan housing will
protrude 12.7mm out of the wall so it may be finished
with plasterboard, etc. See diagram 2
3. Install the air duct run. Secure the duct to the duct
collar on the unit and the fan housing with 3 screws
per end and aluminum duct tape.
Diagram 1:
Front View
Finished
Surface
(12mm)
(12mm)
Front
of Fan
Housing
Diagram 2: Side View - Secure fan housing
to minimum 45mm framing.
Round Air Duct: Attach the 152.4mm round air duct
(supplied) to the fireplace collar and run the duct to
the fan housing. Attach the round-to-oval adapter
to the fan housing and the air duct to the adapter
4. Install the On/Off switch in a convenient location.
This switch controls the fan operation.
NOTE: Variable speed or Rotary 3 speed switch
can be fitted.
5. Wire up the the fan, wall switch and power supply
per local codes. See wiring diagram as reference.
*Electrician to supply wiring.
6. Screw fan junction box to the fan housing.
920-206
45mm
7. Screw the Register Adapter Frame and the
Air Register to the Fan Housing See diagram 4.
45mm
8. Attach collar to base of adaptor with 4 screws
Adjustable
Brackets for
different
wall/floor
thickness.
9. Attach assembly to unit in location shown below
NOTE: Heatwave adaptor may be installed on
Air Duct
Round to Oval
Adapter
Secure with 3 Screws and
Aluminum Duct Tape at Unit
Diagram 4
as shown below.
with 4 screws.
either left of right side.
2
Fan Housing
ACV40E City Series |
installation
12.18.19