Table 6-12
Safety-related segment circuit: Assignment with single-channel actuators; typical parameterization
Parameterization
Assignment
Output
Alarm input IN1
Alarm input IN2
Switch-off delay for stop
category 1
Switch-off delay for stop
category 1
Value range of switch-off
delay for stop category 1
Enable
(VersaSafe only)
GFK-2734 Chapter 6 Connection examples for the safe relay outputs and the safety-related segment circuit
Typical parameterization
Parameterized as
Channel 1
Used
Two-channel
Do not evaluate
Do not evaluate
Enabled
30
Value in s
Enabled
According to the "Value range of switch-off time" and "Switch-off time" parameters, in this
example, the shutdown time is 40 x 10 ms = 400 ms.
According to the "Value range of switch-off delay for stop category 1" and "Switch-off delay
for stop category 1" parameters, in this example, the switch-off delay is 30 x 1 s = 30 s.
Channel 2
Used
Two-channel
Do not evaluate
Do not evaluate
Enabled
30
Value in s
Enabled
Remark
Or disabled
Application-specific
Application-specific
Or disabled
6
6-21