ADF Web HD67078-B2-20 User Manual

ADF Web HD67078-B2-20 User Manual

Profinet / m-bus master - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.100
English
PROFINET / M-Bus Master - Converter
(Order Code: HD67078-B2-20, HD67078-B2-40,
HD67078-B2-80, HD67078-B2-160,
HD67078-B2-250)
For Website information:
www.adfweb.com?Product=HD67078-B2
For Price information:
www.adfweb.com?Price=HD67078-B2-20
www.adfweb.com?Price=HD67078-B2-40
www.adfweb.com?Price=HD67078-B2-80
www.adfweb.com?Price=HD67078-B2-160
www.adfweb.com?Price=HD67078-B2-250
Benefits and Main Features:
Very easy to configure
Up to 250 standard M-Bus devices connected to the
Converter
Power Supply 15...21V AC or 18...35V DC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual PROFINET / M-Bus Master
Document code: MN67078_ENG
Revision 1.100
For others M-Bus products see also the following link:
Converter M-Bus to
www.adfweb.com?Product=HD67021
www.adfweb.com?Product=HD67022
Analyzer / Scanner /Sniffer M-Bus
www.adfweb.com?Product=HD67031
Isolator/Repeater M-Bus
www.adfweb.com?Product=HD67032M
Gateway M-Bus / Modbus RTU
www.adfweb.com?Product=HD67029M-232
www.adfweb.com?Product=HD67029M-485
Gateway M-Bus / Modbus TCP
www.adfweb.com?Product=HD67044
Gateway M-Bus / CANopen
www.adfweb.com?Product=HD67051-B2
Gateway M-Bus / PROFIBUS
www.adfweb.com?Product=HD67053M
Gateway M-Bus Concentrator
www.adfweb.com?Product=HD67054M
Gateway M-Bus Slave / Modbus RTU master
www.adfweb.com?Product=HD67059M-232
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
Page 1 of 40
(RS232)
(RS485)
(on RS232)
(on RS485)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67078-B2-20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67078-B2-20

  • Page 1 Page 1 of 40 Industrial Electronic Devices User Manual Revision 1.100 English PROFINET / M-Bus Master - Converter (Order Code: HD67078-B2-20, HD67078-B2-40, HD67078-B2-80, HD67078-B2-160, HD67078-B2-250) For others M-Bus products see also the following link: For Website information: Converter M-Bus to www.adfweb.com?Product=HD67078-B2...
  • Page 2: Updated Documentation

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 2 of 40 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 3 of 40 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 4 of 40 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 5 of 40 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67078-B2-xxx ADFweb.com S.r.l.
  • Page 6 Wide temperature range: -40°C / 85°C [-40°F / +185°F]. At the Converter can be connected up to 250 standard M-Bus devices. This number depends of the code expressed by the xxx number: HD67078-B2-20 support up to 20 M-Bus devices; HD67078-B2-40 support up to 40 M-Bus devices;...
  • Page 7: Power Supply

    Vmin Vmax Consumption at 24V DC: Device No Load [W/VA] Full Load [W/VA]* HD67078-B2-20 HD67078-B2-40 HD67078-B2-80 HD67078-B2-160 HD67078-B2-250 * This value is with all the Slave M-Bus devices of the code (20, 40, 80, 160, 250) connected to the line...
  • Page 8: Function Modes

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 8 of 40 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device; The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 9 of 40 Industrial Electronic Devices LEDS: The device has got two LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 10 of 40 Industrial Electronic Devices PROFINET: The PROFINET connection must be made using Connector3 of HD67078-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 11 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 11 of 40 Industrial Electronic Devices USE OF COMPOSITOR SW67078: To configure the Converter, use the available software that runs with Windows called SW67078. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Configuration / Open Configuration

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 12 of 40 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “PROFINET Slave / M-Bus Master - Converter”...
  • Page 13: Software Options

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 13 of 40 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 14: Set Communication

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 14 of 40 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, PROFINET and M-Bus. By Pressing the “Set Communication” button from the main window for SW67078 (Fig. 2) the window “Set Communication”...
  • Page 15 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 15 of 40 Industrial Electronic Devices M-BUS By Pressing the “M-Bus” button from the main window for SW67078 (Fig. 2) the window “M-Bus Network” appears (Fig. 4). In the section “Nodes” it is possible to create the nodes of M-Bus line: In the field “Description”...
  • Page 16 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 16 of 40 Industrial Electronic Devices In the field “Send Reset App.” is checked, the converter sends the “Application Reset” command to the slave. In the field “Variables List”...
  • Page 17 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 17 of 40 Industrial Electronic Devices ECTION ARIABLES Selecting the desired node it is possible to add a variable. In order to create a new variable it is necessary to fill these items: To use the created variable the field “Enable...
  • Page 18 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 18 of 40 Industrial Electronic Devices In the field “VIFE” it is possible to select a sub-type of “Type of Data”; If the field “From BCD to Integer” is checked the converter converts the BCD value of variable in Integer format. This happens only if the variable is in BCD format;...
  • Page 19 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 19 of 40 Industrial Electronic Devices SECTION VARIABLES (BY POSITION): Selecting the desired node it is possible to add a variable. In order to create a new variable it is necessary to fill these items: To use the created variable the field “Enable...
  • Page 20 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 20 of 40 Industrial Electronic Devices Having completed this fields, to add the variable the button “ADD VARIABLE” must be pressed. In order to modify a created variable it is necessary to select the desired variable, change the wrong items and then press the “MODIFY VARIABLE”...
  • Page 21 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 21 of 40 Industrial Electronic Devices ASTE AND ELETE TEMS By pressing the right button of the mouse over an item (Variable or Node) it is possible to Copy, Paste and Delete.
  • Page 22 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 22 of 40 Industrial Electronic Devices Possible choices for the fields used to create a variable: Type of Data: Function Field: |_Energy (Wh) |_Instantaneous Value |_Energy (J) |_Minimum Value |_Volume (m |_Maximum Value |_Mass (Kg)
  • Page 23 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 23 of 40 Industrial Electronic Devices VIFE: |_ Period of tariff months(s) |_ Not Selected |_ Period of tariff year(s) |_ Credit of the nominal local legal currency units |_ dimensionless/ no VIF |_ Debit of the nominal local legal currency units |_ Volts...
  • Page 24 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 24 of 40 Industrial Electronic Devices |_ per minute |_ Duration of limit exceed |_ per hour |_ Duration of first/last |_ per day |_ Date(/time) of first/last begin/end |_ per week |_ Multiplicative currection factor |_ per month...
  • Page 25 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 25 of 40 Industrial Electronic Devices Swap Identification: This field is used for select the Swap mode of Identification Number. At the moment there are these possibilities: None; Type 1.
  • Page 26 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 26 of 40 Industrial Electronic Devices To know the meaning of value read in the “Scale” field, you must follow this table (x = Value read in Scale): Description Range Coding Range...
  • Page 27 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 27 of 40 Industrial Electronic Devices Data type F: Min (0 … 59); Hour (0 … 23); Day (1 … 31); Month (1 … 12); Year (0 … 99); Time Invalid (0=Valid, 1=Invalid);...
  • Page 28 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 28 of 40 Industrial Electronic Devices SINGLE SLAVE MODE FUNCTIONING: By checking the field “Single Slave Mode” it is possible to save 512 bytes of data for a single M-Bus Slave Device. For having the data it is necessary that the Master PROFINET writes the first four bytes of his Input Data with the Primary or Secondary Address of the slave which want to receive the data.
  • Page 29: Update Device

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 29 of 40 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 30 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 30 of 40 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67078 device. Warning: If Fig.
  • Page 31 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 31 of 40 Industrial Electronic Devices SCAN & DECODE FUNCTION: “SCAN & DECODE” functions are integrated in the configurator software SW67078. It is possible to access to these functions by simple click on the “...
  • Page 32: Plc Configuration

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 32 of 40 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11-software by Siemens.
  • Page 33 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 33 of 40 Industrial Electronic Devices 2) Press the “Devices and networks” button (1), from the right drop-down menu, under “Other field devicesPROFINET IOGatewayADFWEB.comHD67078” double click on “MBmaster” module (2). Note: If you have installed more than one GSD file, go to the Information section and in the “Version”...
  • Page 34 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 34 of 40 Industrial Electronic Devices 3) Connect the PLC to the HD67078 module by drawing the Ethernet wire between the two Ethernet ports. Then assign the IP Address defined in the Compositor_SW67078 to the HD67078-B2.
  • Page 35 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 35 of 40 Industrial Electronic Devices 4) Then doubleclivk on the “DNSLAVE” label and in the field name change it accordingly to the name defined in the Compositor_SW67078 (2). Then add the main module “Module” and the sub-modules of “Digital Input” and “Digital Output” by double click on the three items in this order “Module”...
  • Page 36 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 36 of 40 Industrial Electronic Devices 5) Load the configuration into the PLC. ADFweb.com S.r.l.
  • Page 37: Mechanical Dimensions

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 37 of 40 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67078-B2-xxx ADFweb.com S.r.l.
  • Page 38: Ordering Informations

    B: Modulbox 4M, 35mm DIN Rail mounting Device Family HD67078: PROFINET / M-Bus Master - Converter Order Code: HD67078-B2-20 Converter PROFINET / M-Bus Master (up to 20 slaves connected to M-Bus) Order Code: HD67078-B2-40 Converter PROFINET / M-Bus Master (up to 40 slaves connected to M-Bus)
  • Page 39 User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 39 of 40 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 40: Warranties And Technical Support

    User Manual PROFINET / M-Bus Master Document code: MN67078_ENG Revision 1.100 Page 40 of 40 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67078-b2-40Hd67078-b2-80Hd67078-b2-160Hd67078-b2-250

Table of Contents