EN
Ø 10
15185
code 15985
image 6
page 28
INSTALLER SECTION
2. DETERGENT DISPENSER RETROFIT
2.1
Electrical connection
Read the electric diagram, enclosed with the machine.
ATTENTION:
output arranged for electrical dispenser 230V max 2 Ampere.
2.2
Pipe connection
a) A Ø12mm hole must be made on the back wall of the appliance. On some models the
hole has already been made and is plugged with a plastic cap.
Remove the cap from the hole and fi t the delivery connection.
b) In case a different injector is fi tted, drill a hole of the same diameter as the injector on the
back wall of the sump (see image 5); this operation must be carried out by the Technical
Service.
The hole must be made above the water level.
It's important to make the hole in a far position from the overfl ow pipe, so that the detergent
does not fl ow out immediately. Fix the detergent dispenser in vertical position, with hose
connections downwards, making sure not to place it on energized components. Clean
the inside of the machine from any drilling residual.
c) Correctly mount the injector
d) Connect the suction hose to the suction connection of the dispenser (see image 5 point
A).
e) Connect the delivery hose to the other connection of the dispenser, and the delivery
fi tting (see image 5 point B).
f) Insert the suction hose with fi lter in the detergent tank.
g) Prime the detergent pump and proceed to dispense.
2.3
Dispensing the detergent
The detergent dispenser capacity can be adjusted using a screwdriver as shown in image 6.
Every 2 cm of product drawn into the tube corresponds to 0.25 cc equivalent to 0.3 g (with
a concentration of 1.2g/cc). For proper dispensing see paragraph 5.2.
C
Point B
min 3
cm
B
Point A
A
C
using the appropriate fi xtures.
CONNECTION DIAGRAM
image 5