12 Technical Specifications

The following specifications are important and vital to the correct operation of the Output Expander. Failure to
adhere to the specifications will result in any warranty or guarantee that was provided becoming null and void.
Power Supply
DC Input Voltage
DC Output Voltage
(DC IN Pass-Through)
Operating Current
Total Combined Current*
Low Voltage Cutout
Low Voltage Restore
Communication
RS-485
Outputs
PGM Outputs
Dimensions
Dimensions (L x W x H)
Weight
Temperature
Operating
Storage
Humidity
* The Total Combined Current refers to the current that will be drawn from the external power supply to supply
the Output Expander
and
connected via electronic fuses to the N+ N- input terminals, and the maximum current is governed by the trip
level of these fuses.
It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not locate the
unit in air conditioning or a boiler room that can exceed the temperature or humidity specifications.
Integrated Control Technology continually strives to increase the performance of its products. As a result these
specifications may change without notice. We recommend consulting our website (http://www.ict.co) for the
latest documentation and product information.
Protege DIN Rail 8 PGM Output Expander
11-14VDC
10.83-14.0VDC 0.7A (Typical) Electronic Shutdown at 1.1A
80mA (Typical)
3.25A (Max)
8.7VDC
10.5VDC
Module Network
8 FORM C Relays, 7A 250V Max
156.8 x 90 x 60mm (6.17 x 3.54 x 2.36")
482g (17oz)
0˚-50˚C (32˚ - 122˚F)
-10˚- 85˚C (14˚ - 185˚F)
0%-93% non-condensing, indoor use only (relative humidity)
any devices connected to the Expander's outputs. The Auxiliary outputs are directly