ICT PRT-ZX1 Installation Manual

Protege single input expander

Advertisement

Quick Links

PRT-ZX1
Protege Single Input Expander
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for ICT PRT-ZX1

  • Page 1 PRT-ZX1 Protege Single Input Expander Installation Manual...
  • Page 2 Protege® Logo are registered trademarks of Integrated Control Technology Limited. All other brand or product names are trademarks or registered trademarks of their respective holders. Copyright © Integrated Control Technology Limited 2003-2022. All rights reserved. Last Published: 16-Jun-22 11:43 AM PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 3: Table Of Contents

    DC Power & Encrypted Module Network Installation Wiring Input Address Configuration Technical Specifications New Zealand and Australia European Standards UK Conformity Assessment Mark FCC Compliance Statements Industry Canada Statement Disclaimer and Warranty PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 4: Protege Single Input Expander

    The current features of the input expander include: ⦁ Secure encrypted RS-485 module communications ⦁ 1 input ⦁ 4 state input alarm using resistors to provide short, alarm, closed and tamper conditions ⦁ Online and remote upgradable firmware PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 5: Installation Requirements

    Installation Requirements This equipment is to be installed in accordance with: The product installation instructions ⦁ AS/NZS 2201.1 Intruder Alarm Systems ⦁ The Local Authority Having Jurisdiction (AHJ) ⦁ PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 6: Dc Power & Encrypted Module Network

    NB terminals of the first and last modules on the RS-485 network. These are the modules physically located at the ends of the RS-485 network cabling. End of Line Resistors: First Module on RS-485 Network Last Module on RS-485 Network 330R 330R From Next Previous Module Module PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 7: Installation Wiring

    Installation Wiring The input expander comes supplied with a 5-pin expansion connector. +12V BLACK GREEN WHITE ORANGE INPUT 1 Color Function +12VDC Black Green White Orange Input 1 PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 8: Input

    When using the 'No Resistor' configuration the controller only monitors the opened and closed state of the connected input device, generating the alarm (open) and restore (closed/sealed) conditions. No EOL Resistor Input Configuration N.C Input Contact 0V BLACK INPUT 1 ORANGE PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 9: Address Configuration

    The controller has a set limit on the number of modules of each type that it can support. When adding and configuring modules always refer to the Maximum Module Addresses table in the controller installation manual. PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 10: Technical Specifications

    Integrated Control Technology continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest documentation and product information.
  • Page 11: New Zealand And Australia

    New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 12: European Standards

    Tests EMC (operational) according to EN 55032:2015 Radiated disturbance EN 55032:2015 Power frequency magnetic field immunity tests (EN 61000-4-8) EN50131 In order to comply with EN 50131-1 the following points should be noted: PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 13 ATTACK, comply with the EN 50131 standards. Tamper protection against removal of the cover as well as removal from mounting is provided by tamper switch. Warning: Enclosures supplied by 3rd parties may not be EN50131-compliant, and should not be claimed as such. PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 14: Uk Conformity Assessment Mark

    UK Conformity Assessment Mark General Product Statement The UKCA Compliance Label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 15: Fcc Compliance Statements

    NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 16: Industry Canada Statement

    Industry Canada Statement ICES-003 This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CAN ICES-3 (A)/NMB-3(A) PRT-ZX1 | Protege Single Input Expander | Installation Manual...
  • Page 17: Disclaimer And Warranty

    Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information. In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.
  • Page 18 In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.

Table of Contents