Maintenance and diagnostics

This section describes the maintenance and diagnostic programs used on the Call Server for
the UDT card.

LD programs

LD 60 Digital trunk loop and clock controller maintenance

Table 29: LD 60 Digital trunk loop maintenance
Commands
DISI loop
DISL loop
DSCH l ch
DSYL loop
ENCH loop
ENCH l ch
ENLL loop
ENYL loop
SLFT loop
SLFT l ch
LCNT (loop)
RLBK loop
RLBK loop ch Performs external loop back test on channel ch of loop. (Channel must be
STAT
STAT loop
STAT loop ch Get status of channel
ISDN Primary Rate Interface Maintenance
Description
Disable loop when all channels are idle
Disable network and DTI/PRI cards of loop
Disable channel ch of loop
Disable yellow alarm processing for loop
Enable all channels on 2.0 Mb/s DTI/PRI
Enable channel ch of DTI/PRI loop
Enable network and DTI/PRI cards of loop
Enable yellow alarm processing for loop
Invoke hardware self-test on loop.
Invoke partial hardware self-test on channel ch.
List contents of alarm counters on one or all DTI/PRI loops
Performs external loop back test on loop. (Card must be disabled.)
disabled.)
Get status of all loops
Get status of DTI/PRI loop
Maintenance and diagnostics
November 2011
93