Download Print this page

ADF Web HD67591-232-A1 User Manual

Ethernet/ip / modbus master - converter
Hide thumbs Also See for HD67591-232-A1:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.002
English
EtherNet/IP / Modbus Master - Converter
(Order Code: HD67591-232-A1, HD67591-485-A1,
HD67591-422-A1)
For Website information:
www.adfweb.com?Product=HD67591
For Price information:
www.adfweb.com?Price=HD67591-232-A1
www.adfweb.com?Price=HD67591-485-A1
www.adfweb.com?Price=HD67591-485-A1
Benefits and Main Features:
Electrical isolation
Two EtherNet/IP ports
Temperature range: -40°C/85°C (-40°F/185°F)
User manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual EtherNet/IP / Modbus Master - Converter
Document code: MN67591_ENG
Revision 1.002
For others Ethernet/IP products see also the following link:
Converter EtherNet/IP to
www.adfweb.com?Product=HD67077
www.adfweb.com?Product=HD67091
www.adfweb.com?Product=HD67159
www.adfweb.com?Product=HD67174
www.adfweb.com?Product=HD67588
www.adfweb.com?Product=HD67589
www.adfweb.com?Product=HD67590
www.adfweb.com?Product=HD67592
www.adfweb.com?Product=HD67593
www.adfweb.com?Product=HD67594
www.adfweb.com?Product=HD67595
www.adfweb.com?Product=HD67596
www.adfweb.com?Product=HD67597
www.adfweb.com?Product=HD67598
www.adfweb.com?Product=HD67599
www.adfweb.com?Product=HD67660
www.adfweb.com?Product=HD67663
www.adfweb.com?Product=HD67664
www.adfweb.com?Product=HD67682
www.adfweb.com?Product=HD67722
www.adfweb.com?Product=HD67744
www.adfweb.com?Product=HD67807
www.adfweb.com?Product=HD67840
www.adfweb.com?Product=HD67871
www.adfweb.com?Product=HD67906
www.adfweb.com?Product=HD67945
www.adfweb.com?Product=HD67974
www.adfweb.com?Product=HD67B16
www.adfweb.com?Product=HD67B39
www.adfweb.com?Product=HD67B78
www.adfweb.com?Product=HD67C63
www.adfweb.com?Product=HD67D25
www.adfweb.com?Product=HD67E27
www.adfweb.com?Product=HD67E77
www.adfweb.com?Product=HD67F25
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Pagina 1 di 36
(M-Bus)
(M-Bus Wireless)
(SNMP Agent)
(SNMP Manager)
(DMX)
(NMEA 2000)
(Serial)
(Modbus Slave)
(PROFIBUS Master)
(PROFIBUS Slave)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(J1939)
(PROFINET Slave)
(Modbus TCP Slave)
(Modbus TCP Master)
(BACnet IP Slave)
(BACnet IP Master)
(IEC 61850 Server)
(KNX)
(DALI)
(IO-Link Master)
(HART)
(MQTT)
(IO-Link Slave)
(OPC UA Client)
(OPC UA Server)
(PROFINET Master)
(EnOcean)
(LoRaWAN)
(EtherCAT Slave)
(EtherCAT Master)
(LoRaWAN Gateway)
Phone +39.0438.30.91.31

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67591-232-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67591-232-A1

  • Page 1 English www.adfweb.com?Product=HD67159 (SNMP Agent) www.adfweb.com?Product=HD67174 (SNMP Manager) www.adfweb.com?Product=HD67588 (DMX) EtherNet/IP / Modbus Master - Converter www.adfweb.com?Product=HD67589 (NMEA 2000) www.adfweb.com?Product=HD67590 (Serial) (Order Code: HD67591-232-A1, HD67591-485-A1, www.adfweb.com?Product=HD67592 (Modbus Slave) HD67591-422-A1) www.adfweb.com?Product=HD67593 (PROFIBUS Master) www.adfweb.com?Product=HD67594 (PROFIBUS Slave) www.adfweb.com?Product=HD67595 (CAN) For Website information: www.adfweb.com?Product=HD67596 (CANopen) www.adfweb.com?Product=HD67591...
  • Page 2: Updated Documentation

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 2 di 36 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: Page Updated ...
  • Page 3: Security Alert

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 3 di 36 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Example Of Connection

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 4 di 36 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 5 di 36 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67591-232-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 6 di 36 Industrial Electronic Devices Figure 1b: Connection scheme for HD67591-485-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 7 di 36 Industrial Electronic Devices Figure 1c: Connection scheme for HD67591-422-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8 Pagina 8 di 36 Industrial Electronic Devices CHARACTERISTICS: The HD67591-232-A1, HD67591-485-A1 and HD67591-422-A1 are a EtherNet/IP / Modbus Master Converter. It allows the following characteristics: Up to 496 bytes in reading and 496 bytes in writing; Two-directional information between Modbus bus and EtherNet/IP bus;...
  • Page 9: Power Supply

    The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67591-232-A1 HD67591-485-A1 HD67591-422-A1 Caution: Not reverse the polarity power HD67591-xxx-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com...
  • Page 10: Function Modes

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 10 di 36 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 11 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 11 di 36 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 12 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 12 di 36 Industrial Electronic Devices ETHERNET: The Ethernet connection must be made using Connector3 and/or Connector4 of HD67591-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 13 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 13 di 36 Industrial Electronic Devices RS485: For terminate the RS485 line with a 220Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet).
  • Page 14 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 14 di 36 Industrial Electronic Devices RS232: The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a serial cable where the pins 2 and 3 are crossed).
  • Page 15 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 15 di 36 Industrial Electronic Devices USE OF COMPOSITOR SW67591: To configure the Converter, use the available software that runs with Windows called SW67591. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 16: New Configuration / Open Configuration

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 16 di 36 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “EtherNet/IP / Modbus Master - Converter”...
  • Page 17: Software Options

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 17 di 36 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 18 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 18 di 36 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 19: Set Communication

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 19 di 36 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, EtherNet/IP and Modbus. By Pressing the “Set Communication” button from the main window for SW67591 (Fig. 2) the window “Set Communication”...
  • Page 20: Set Access

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 20 di 36 Industrial Electronic Devices SET ACCESS: By pressing the “Set Access” button from the main window for SW67591 (Fig. 2) the window “Set Access” appears. This window is divided in two parts, the "Modbus Read"...
  • Page 21: Modbus Write

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 21 di 36 Industrial Electronic Devices MODBUS WRITE The means of the fields are: In the field “Slave ID” the address of the Modbus device that you must write is defined; In the field “Type”...
  • Page 22: Update Device

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 22 di 36 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 23 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 23 di 36 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67591 device. Warning: If Fig.
  • Page 24 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 24 di 36 Industrial Electronic Devices MODBUS DIAGNOSTIC OVER ETHERNET/IP: During the normal functioning of the device, if all the programmed Modbus requests have received a valid reply (not an exception error), every EtherNet/IP frame has the "Data Status"...
  • Page 25: Advanced Functions

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 25 di 36 Industrial Electronic Devices ADVANCED FUNCTIONS: In the HD67591-xxx-A1 are implemented some advanced commands that allows to check the functioning of the converter and send some Modbus commands directly from Ethernet side.
  • Page 26 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 26 di 36 Industrial Electronic Devices B1 command This command allows to read the status of the enabling/disabling of the Modbus polls. REQ: Byte 0 0xB1 RES: Byte 0 B1/bit0...
  • Page 27 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 27 di 36 Industrial Electronic Devices B2 command This command allows to see the number of errors for each Modbus poll defined in the section “Set Access”. REQ: Byte 0 0xB2...
  • Page 28 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 28 di 36 Industrial Electronic Devices B3 command This command allows to enable the Transparent: it will be possible to send Modbus commands directly from Ethernet side. The converter will become completely transparent.
  • Page 29 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 29 di 36 Industrial Electronic Devices B5 command This command allows to enable/disable the polling to a single Modbus slave. REQ: Byte 0 Byte 1 Byte 2 0xB5 Slave ID 0x00/0x01...
  • Page 30 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 30 di 36 Industrial Electronic Devices B6 command This command allows to enable/disable a single poll on Modbus side. REQ: Byte 0 Byte 1 Byte 2 0xB6 Poll No 0x00/0x01...
  • Page 31: Mechanical Dimensions

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 31 di 36 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7a: Mechanical dimensions scheme for HD67591-232-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 32 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 32 di 36 Industrial Electronic Devices Figure 7b: Mechanical dimensions scheme for HD67591-485-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 33 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 33 di 36 Industrial Electronic Devices Figure 7c: Mechanical dimensions scheme for HD67591-422-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 34: Ordering Informations

    232: RS232 485: RS485 422: RS422 Device Family HD67591: EtherNet/IP / Modbus Master - Converter Order Code: HD67591-232-A1 Converter EtherNet/IP / Modbus Master Converter (RS232 serial) Order Code: HD67591-485-A1 Converter EtherNet/IP / Modbus Master Converter (RS485 serial) Order Code: HD67591-422-A1...
  • Page 35 User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 35 di 36 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 36: Warranties And Technical Support

    User Manual EtherNet/IP / Modbus Master - Converter Document code: MN67591_ENG Revision 1.002 Pagina 36 di 36 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

This manual is also suitable for:

Hd67591-485-a1Hd67591-422-a1