3.3 I Operating

• Check that there are no tools or other foreign objects in the machine.
• The panel that provides access to the technical section must be put in place.
• Set the valves as follows: valve B wide open, valves A, C, D and E closed
• An incorrect by-pass setting may cause the heat pump to malfunction.
• Check that the hydraulic corrections are correctly tightened and that there are no leaks.
• Check that the device is fully stable.
• Set the water circulation running.
• Close valve B gradually so that the filter pressure is increased by 150g (0.150 bars).
• Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
filtration circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
• Connect the power supply to the heat pump:
Press and hold
for 2 seconds
• Device starts after a timer of up to 5 minutes,
• Set the temperature you want ("setpoint" temperature) by pressing
• After the steps to start up your heat pump, stop the water circulation temporarily to check that your device stops after
a few seconds (by activating the flow controller):
Information: light water flow
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve (optional)
: water exit adjustment valve (optional)
program version number (different according to model)
Screen saver
Splash screen
Temperature setpoint
or
.
the water flow light must flash.