2.1 I Selecting the location

• When installed with and protected by an appropriate Residual Current Device (RCD) having
a maximum trip current rating of 30mA, the appliance must be installed at 2 metres,
minimum, from the surrounding edge of the pool.
• If an appropriate RCD is not installed with the appliance, the appliance must be installed at a
minimum distance of 3.5 metres from the edge of the pool.
• Do not lift the device by the body; use its base.
• Install the device outdoors; provide free space around it (see § "2.2 I Hydraulic connections").
• Place the device on its anti-vibration studs (integrated under its base) on a stable, solid and level surface,
• This surface must be able to bear the weight of the device (in particular in the case of installation on a roof, a balcony
or any other support).
• The device may be secured to the ground using the holes in the base of the device or with rails (not supplied). A
drilling scale is available on the back of the packaging carton.
Top view of the device with dimensions for attachment to the ground
The device must not be installed:
• In a closed and unventilated room
• In a location subject to high winds,
• With the blowing towards a permanent or temporary obstacle (window, wall, hedge, awning, etc.) less than 3 metres
away,
• Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),
• Near a heat source or flammable gas,
• Near high frequency equipment,
• In a location where it would be subject to snow build-up,
• In a location where it might be flooded by the condensation produced by the device when operating.
Tips: reduce any noise annoyance from your heat pump
• Do not install it under or towards a window.
• Do not tilt it towards your neighbours.
• Install it in a clear space (the sound waves are reflected on surfaces).
• Install an acoustic screen around the heat pump, respecting the distances.
• Install the anti-vibration studs under the heat pump and replace them regularly.
• Install 50cm of flexible PVC pipe at the heat pump water input and output (stops vibrations).