D1260/D1260B | Owner's Manual | Part III: Advanced Commands - SERVICE MENU ? (9 + 9 + Enter)
Using Print Log
Print Log ?>
1. Press the
2. The display changes to
Print all events>
Press the
events in the log.
<Exit
Press the
soft key to exit this function and
return to idle text.
The events are sent to a connected printer and
Printing all events in history
display changes to
for three seconds before returning to idle text.
3. Enter the start date in the form of mm/dd.
For example, to enter 12/21 as the start date, press
1 + 2 + 2 + 1
.
Once you start entering digits, the
events>
soft key is replaced with the
key.
Enter>
Press either the
button.
Bosch Security Systems | 9/04 | 50410D
soft key.
Enter start date:
soft key to print all
Print all
Enter>
soft
soft key or the ENTER
4. If the date entered is valid, the events for that date
will be sent to a connected printer and the display
will show
Printing events.
before returning to idle text.
Using Display Rev
Display Rev ?>
1. Press the
2. The display will change to
Version 6-40
(D9412 and 6-40 are used as an example, other
panels could be D9112, D7412, D7212).
3. The display will return to idle text after 5 seconds.
Using Service Walk Test
The Service Walk Test function is only
available in the Service Menu for D9412
and D9112 panels. If the panel model is
D7412 or D7212, the Service Walk Test
will have to be enabled on the Function
list for the command center through the
panel's programming.
1. When the display shows
be tested
you can begin. (### is the number of
points).
for three seconds,
soft key.
*Bosch D9412*
### points remain to
65