Festo CPV DI02 Series Brief Description page 19

Cpv valve terminal with direct connection, profibus-dp
Hide thumbs Also See for CPV DI02 Series:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
6
Diagnosis via LEDs
LED
Operating status and fault display
PS
Operating
(green)
(green)
voltage supply
voltage supply
(pin 1)
PL
Load voltage
(green)
supply (pin 2)
BF
Bus fault
P
Other faults
Festo CPV...−GE−DI02−8 0704NH English
flashes: Undervoltage
off: Operating voltage not applied
flashes fast: Undervoltage in valves of
CPV Direct
flashes slowly: Undervoltage in valves/
outputs in the CP string extension
off: Load voltage is not applied
flashes fast: Non−permitted station number
set with DIL switch
flashes slowly: Field bus connection not OK
lights up: Hardware fault (servicing
required)
flashes fast: Configuration fault in CP string
flashes slowly: Module in the CP string has
diagnostic case
lights up: Module failure in the CP string
19