Download Print this page

Valmont Industries INGAL CIVIL SoftStop Product Manual page 33

Tangent end terminal

Advertisement

PARTS LIST
PART NO.
QTY.
DESCRIPTION
10007537
3
SoftStop Terminal Guardrail
000011
10007540
6
SoftStop Line Post 1830mm
000533
CENTERLINE OF POSTS #0 & #1
10001397
7
KING BLOCK
006777
10001402
1
SFST SYT Post #2 1830mm
015000
10007536
1
SFST-ANCHOR G.RAIL
015200
10007544
2
SFST-ANCHOR ANGLE
015201
10007547
1
SFST-ANGLE STRUT
015202
10007539
1
SFST-POST#1 SYTP
015203
10007542
1
SFST-ANCHOR PADDLE
015204
10007543
1
SFST-POST#0
015205
B
10007546
1
SFST-PLATE WASHER
015206
10007545
1
SFST-KEEPER PLATE
015207
10007538
1
SFST-IMPACT HEAD
015208
0
~ HARDWARE ~
10007554
6
5/16 ROUND WASHER WIDE
003240
10007555
3
5/16 HEX NUT
003245
10001299
41
5/8" GR HEX NUT
003340
1397
10007550
32
5/8"X1.25" GR BOLT
003360
10007092
1
5/8"X1.75" HEX BOLT A325
003391
REFERENCE LINE
10001300
7
5/8"X10" GR BOLT A307
003500
PARALLEL TO GRADE
10001284
4
3/4" ROUND WASHER F436
003701
10001285
2
3/4" HVY HEX NUT A563 DH
003704
10001286
2
3/4"X2.5" HEX BOLT A325
003717
10007549
1
1" HVY HEX NUT A563 DH
003908
A
10007095
4
5/8" WASHER F436
004372
10007551
1
5/8"X9" HEX BOLT A325
004489
10007548
1
1" ROUND WASHER F436
004902
10007552
2
5/16"X2.5" HEX BOLT GRD 5
105285
10007553
1
5/16"X1.5" HEX BOLT GRD 5
105286
10001300
DO NOT ATTACH
RAIL AT POST #2
10007536
10001299
10001299
10001402
10001397
10007540
SECTION G-G
(POST #2)
4
04-06-2019
HEIGHT OF ANCHOR ANGLES UPDATED
VB
LG
3
04-02-2019
MIRRORED DRAWING TO MATCH LEADING TERMINAL
VB
LG
2
25-07-2016
DRAWING LAYOUT UPDATED
MC
SE
1
01-10-2015
BOM UPDATED
LG
SE
BACK OF POST #2 - #8
LENGTH OF NEED
C
1
2
3
4051
1727
1905
SEE NOTE 6
G
D
10007536
10007537
10007538
I
DO NOT ATTACH
RAIL AT POST #2
G
YIELDING HOLES
APPROXIMATELY
CENTERED AT
GROUND LINE
DETAIL I
POSTS #1 & #2
10007552
10007548
10007549
10001300
10007537
10007095
10001397
10001299
10007553
SECTION F-F
10007554
(POST #3 - #8)
10007538
DETAIL D
DRAWN
CHECKED
LG
LG
APPROVED
LG
LG
SCALE
ISSUE FOR
NOTE:
INSTALL SoftStop PARALLEL TO ROADWAY.
WHEN OFFSET IS REQUIRED BY DESIGN ENGINEER,
SEE SoftStop MANUAL FOR REQUIREMENTS.
4
5
1905
1905
1905
F
10007537
F
10007548
10007549
1" NUT SHALL BE
SECURELY TIGHTENED
AFTER FINAL ASSEMBLY,
BUT NOT DEFORMING THE
KEEPER PLATE (10007545)
10007551
10007542
10007547
10007544
10007095
10007555
2 PLACES
10007544
10007536
10007542
DETAIL B
(AT ANCHOR POST#0)
10007538
10007547
10007092
10007095
10007095
10007555
10007539
10001299
10007554
10007539
DETAIL C
(POST #1, SHOWN NEAR GROUND)
(POST #1)
NAME
DATE
TRIN
14-11-2012
C I V I L P R O D U C T S
LG
28-05-2015
A
valmont
COMPANY
LG
28-05-2015
N.T.S.
@
A3
INFORMATION ONLY
MASH TEST LEVEL 3 (TL-3) SoftStop TERMINAL
6
7
8
1905
1905
10007537
10007545
10007542
10007552
2 PLACES
2 PLACES
10007554
2 PLACES
10007546
10007554
10007542
2 PLACES
E
10007536
H
10007544
10007547
10007543
(ORIENT SO VERTICAL LEG IS DOWN)
POST #0
DETAIL A
NOTES:
1. REFER TO SoftStop ASSEMBLY MANUAL.
2. PROPER SITE GRADING SHOULD BE ACCOMPLISHED IN ACCORDANCE WITH
LOCAL SPECIFYING AGENCY GUIDELINES AND THE AASHTO ROADSIDE
DESIGN GUIDE.
3. DO NOT ATTACH THE SoftStop DIRECTLY TO A RIGID BARRIER.
4. UNDER NO CIRCUMSTANCES SHALL THE GUARDRAIL WITHIN THE SoftStop
BE CURVED.
5. MANUFACTURER SUGGESTS CUSTOMER TO PROVIDE REFLECTORIZATION
OF THE TERMINAL.
6. IT IS ACCEPTABLE TO INSTALL THE SoftStop IMPACT HEAD PARALLEL TO THE
GRADE LINE OR WITH AN UPWARD TILT. SEE SoftStop ASSEMBLY MANUAL FOR
SPECIFIC DETAILS.
GUARDRAIL END TERMINAL
SOFTSTOP
GENERAL ARRANGEMENT
10001285
10001284
10001284
10001286
FLATTENED
(4 PLIES)
10007556
SS-STD-001
4
Rev:

Advertisement

loading