Download Print this page

Installation Procedure - Valmont Industries INGAL CIVIL SoftStop Product Manual

Tangent end terminal

Advertisement

SoftStop
® Tangent End Terminal

8.0 INSTALLATION PROCEDURE

STEP 1
System Line Post Assembly (Posts 3-8)
PARTS
G
10007540
6 EA
Use only Trinity Highway parts
that are speci ed herein for the
SoftStop® System for assembling,
maintaining, or repairing the
SoftStop® System. Do not utilise
or otherwise comingle parts from
other systems even if those systems
are Trinity Highway systems.
Release 06/19
1. Assemble all parts in the con guration & orientation as shown in the above
diagram.
2. The SoftStop® System must be attached to a w-beam guardrail that has been
properly transitioned to 787 mm rail height per state/specifying agency (see
Appendix for transition drawing example).
3. Establish the location of the last post of the SoftStop® System (Post 8) by placing
a level on the face of downstream guardrail to the nished grade and applying
o set and post spacing requirements shown above.
4. Ensure proper post spacing and post height is achieved for Posts 3-8 (Part G) per
shown dimensions above.
Proper site grading must be accomplished in accordance
with local specifying agency guidelines. Failure to follow
this warning could result in serious injury or death in the
event of a vehicle impact or collision with the system.
INSTRUCTIONS
WARNINGS
17

Advertisement

loading