Warranty and liability
All claims to warranty and liability will be rendered invalid if
The product was used contrary to the purpose for which it is intended
}
Damage can be attributed to not having followed the guidelines in the manual
}
Operating personnel are not suitably qualified
}
Any type of modification has been made (e.g. exchanging components on the PCB
}
boards, soldering work etc.).

Disposal

When decommissioning, please comply with local regulations regarding the disposal of
}
electronic devices (e.g. Electrical and Electronic Equipment Act).
Unit features
Signal lamp for muting operation
}
Scope of supply:
}
Function description
In muting mode, the operator must be made aware of the hazard that results from the sus­
pension of the safety function. The muting lamp is designed for this purpose. It illuminates
as soon as muting mode is started.
Installation and wiring
The cover must be taken off and the bulb removed for installation and wiring:
Turn the cover to the right and pull it off upwards.
}
While applying slight downward pressure, rotate the bulb by approx. 90° to the right and
}
pull it out.
Fig.: Take off the cover and remove the bulb
Operating Manual PIT si1.1
21040­EN­03
Muting lamp including bulb
mounting bracket
2 screws
6