Xinje ZG3 Series User Manual page 86

Integrated plc&hmi
Table of Contents

Advertisement

SFD1940
Pulse parameters setting
SFD1941
Low 16 bits of pulse number per
SFD1942
circle
High 16 bits of pulse number per
SFD1943
circle
Low 16 bits of pulse equivalent
SFD1944
per circle
High 16 bits of pulse equivalent
SFD1945
per circle
SFD1946
Pulse direction terminal
SFD1947
Direction delay time
Positive compensation of gear
SFD1948
gap
Negative compensation of gear
SFD1949
gap
Low 16 bits of Electrical origin
SFD1950
position
High 16 bits of Electrical origin
SFD1951
position
Mechanical
SFD1952
parameter setting
Terminal setting of near point
SFD1953
signal
SFD1954
Z phase terminal setting
SFD1955
Limit terminal setting
Bit 0:logic of pulse output
0:positive logic;
1:negative logic , default is 0
Bit 1:logic of pulse direction
0:positive logic;
1:negative logic , default is 0
Bit 8:pulse unit
0:pulse number;
1:pulse equivalent, default is 0
Assign the number of terminal Y,
0xFF for no terminal
Default 20,unit:ms
Negative compensation will also
use this data when gear gap
negative compensation =0
Bit0:Switch state setting of near
back
to
origin
point, 0 : Normally ON ;
1Normally OFF
Bit0~bit7:Assign the number of
terminal X, 0Xff for not terminal
Bit0~bit7:Assign the number of
terminal X, 0Xff for not terminal
Bit7~bit0: Assign limit 1 number
of terminal X, 0Xff for not
terminal
Bit15~bit8 : Assign limit 2
number of terminal X, 0Xff for
not terminal
Public
PULS
parameters
E_9

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Xinje ZG3 Series

This manual is also suitable for:

Zg3-30rZg3-30tZg3-30prZg3-30pt