COM 2
SFD610*
Communication mode
SFD611*
Communication format
Judgment time of frame
SFD612*
timeout
Judgment time of reply
SFD613*
timeout
Waiting time before
SFD614
sending
Timeout:
If 'judgment time of frame timeout' is set 0, then it will finish after accepting one character;8bit
unsigned number.
If 'judgment time of reply timeout is set' 0, it means no timeout waiting;16bits unsigned number.
If 'waiting time before sending' is set 0, it means no time-lapse; 16 bit unsigned number.
Value meaning of SFD600, SFD610 corresponding bits
Corresponding bit
0~7:Modbus station number Modbus station number
8~15:Communication mode 0:modbus RTU mode (default value)
Value meaning of SFD601, SFD611 corresponding bits
Corresponding bit
0~3:Baud rate
4~7:Data bit
8~11:Stop bit
12~15:Odd-even parity
Reserved Motion Control Usage
ID
Function
Baud rate, data bit,
stop bit,parity
Value meaning
1:modbus ASCII mode
2:free-format
Value meaning
0x0,
0x1,
BaudRate600
BaudRate1200
0x4,
0x5,
BaudRate9600
BaudRate19200
0x8,
0x9,
BaudRate115200
BaudRate192000
0xC,
0xD,
BaudRate384000
BaudRate512000
0x0,8 bits
0x1,7 bits
0x0,2 bits
0x0,none
0x1,odd parity
Description
Refer to the value meaning of
corresponding bit
Refer to the value meaning of
corresponding bit
Unit: ms
Unit: ms,if value is set 0, it means
no timeout waiting
Unit: ms
0x2,
BaudRate2400
0x6,
BaudRate38400
0xA,
BaudRate256000
0xE,
BaudRate576000
0x2,1bit
0x2,even parity
0x3,
BaudRate4800
0x7,
BaudRate57600
0xB,
BaudRate288000
0xF,
BaudRate768000