Getting Started; Overview; Digital Section - ST X-NUCLEO-OUT10A1 User Manual

Getting started with industrial digital output expansion board for stm32 nucleo
Table of Contents

Advertisement

1

Getting started

1.1

Overview

The
X-NUCLEO-OUT10A1
switch (IPS), is designed to meet the application requirement in terms of galvanic isolation between user interface
(or logic side) and power interface (or process side).
This requirement is satisfied by an optical isolation implemented through two couples of optocouplers:
1.
The first couple includes:
a.
ISO1: for signal forwarding to the device
and
b.
ISO2: for diagnostic signal (DIAG pin) feedback
2.
The second couple incudes:
a.
ISO3: for the additional output voltage feedback signal
and
b.
ISO4: for the additional circuitry driving Q1 to allow fast discharge of the output rail
The main features of the
Based on
Operating range up to 60 V/0.7 A
Low power dissipation (R
Fast decay for inductive loads
Open load detection and diagnostics
Overload and overheating protections with thermal shut-down and cut-off
PowerSSO-12L package
Application board operating range: 12 - 33 V, 0 to 0.7 A
Extended voltage operating range (J1 open) up to 60 V
Green LED for output ON/OFF status
Red LED for diagnostics (open load, cut-off and overheating)
3 kV galvanic isolation
Supply rail reverse polarity protection
Ready for Safety Digital Output Architecture
EMC compliance according to IEC61000-4-2, IEC61000-4-3, IEC61000-4-5
Wide application development potential in
Equipped with Arduino™ UNO R3 connectors
CE certified
RoHS and China RoHS compliant
1.1.1

Digital section

The digital section is associated with the STM32 interface and digital supply voltage to and from the
OUT10A1
expansion board.
The digital and power sections are isolated by 3.3 mm creepage. Communication between the two sections is
guaranteed by ISO1, ISO2, ISO3 and ISO4 optocouplers.
UM2716 - Rev 1
industrial digital output expansion board, embedding the
X-NUCLEO-OUT10A1
IPS161HF
single high-side switch with the following main features:
ON(MAX)
expansion board are:
= 120 mΩ)
STM32 Nucleo
development environment
UM2716
Getting started
IPS161HF
intelligent power
X-NUCLEO-
page 2/16