Siemens CM 1542-1 Operating Instructions Manual page 29

For simatic net s7-1500 - profinet
Hide thumbs Also See for CM 1542-1:
Table of Contents

Advertisement

● Default of the port
– Open
– Closed
– Open
– Open after configuration
– Open (login, when configured)
– Open with block call
● Authentication
Specifies whether or not the protocol authenticates the communications partner during
access.
Protocol /
Port number (pro-
function
tocol)
DCP
93 (UDP)
S7 communica-
102 (TCP)
tion
HTTP
80 (TCP)
SNMP
161 (UDP)
PROFINET
34964 (UDP)
Ports of communication partners and routers
Make sure that you enable the required client ports in the corresponding firewall on the
communications partners and in intermediary routers.
These can be:
● DHCP / 67, 68 (UDP)
● DNS / 53 (UDP)
● NTP / 123 (UDP)
● SMTP / 25 (TCP) - Open in CP on block call (outgoing only)
CM 1542-1
Operating Instructions, 07/2019, C79000-G8976-C355-04
The port is open at the start of the configuration.
The port is closed at the start of the configuration.
Port status
The port is always open and cannot be closed.
The port is open if it has been configured.
As default the port is open. After configuring the port, the communications partner
needs to log in.
The port is only opened when a suitable program block is called.
Default of the port
Open
Open
Closed
Open
Open
Port status
Open
Open
Open after configuration
Open
Open
Configuration, programming
4.1 Security recommendations
Authentication
No
No
No
No
No
29