Table 6- 2
Technical data for the dv/dt filter plus Voltage Peak Limiter, 380 V – 480 V 3 AC, Part 1
Order number
Suitable for Power Module
Type rating of the Power
Module
I
thmax
Degree of protection
dv/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- to the Power Module
- load
- PE
Max. permissible cable
length between dv/dt reactor
and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage Peak Limiter
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- to the dV/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
32
6SL3000-
2DE32-6AA0
6SL3310-
1GE32-1AAx
kW
110
A
260
IP00
kW
0.701
kW
0.729
kW
0.78
M10
M10
M6
m
mm
410
mm
370
mm
229
kg
66
kW
0.029
kW
0.027
kW
0.025
M8
M8
M8
mm
263
mm
265
mm
188
kg
6
2DE32-6AA0
2DE35-0AA0
1GE32-6AAx
1GE33-1AAx
132
160
260
490
IP00
IP00
0.701
0.874
0.729
0.904
0.78
0.963
M10
M12
M10
M12
M6
300 (shielded)
450 (unshielded)
410
460
370
370
229
275
66
122
0.029
0.042
0.027
0.039
0.025
0.036
M8
Terminal 70 mm²
M8
Terminal 70 mm²
M8
Terminal 35 mm²
263
392
265
285
188
210
6
dV/dt filter plus Voltage Peak Limiter
Operating Instructions, 03/2012, A5E00692302A
2DE35-0AA0
1GE33-8AAx
200
490
IP00
0.874
0.904
0.963
M12
M12
M6
M6
460
370
275
122
0.042
0.039
0.036
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
392
285
210
16