Table 6- 5
Technical specifications for the dv/dt filter plus Voltage Peak Limiter, 500 V – 600 V 3 AC, Part 1
Order number
Suitable for Power Module
Type rating of the Power
Module
I
thmax
Degree of protection
dV/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- to the Power Module
- load
- PE
Max. permissible cable
length between dV/dt reactor
and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage Peak Limiter
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- to the dV/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
dV/dt filter plus Voltage Peak Limiter
Operating Instructions, 03/2012, A5E00692302A
6SL3000-
2DH32-2AA0
6SL3310-
1GF31-8AAx
kW
110
A
215
IP00
kW
0.578
kW
0.604
kW
0.645
M10
M10
M6
m
mm
460
mm
360
mm
275
kg
83
kW
0.032
kW
0.03
kW
0.027
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
mm
392
mm
285
mm
210
kg
16
2DH32-2AA0
2DH33-3AA0
1GF32-2AAx
1GF32-6AAx
132
215
IP00
0.578
0.604
0.645
M10
M10
M6
300 (shielded)
450 (unshielded)
460
360
275
83
0.032
0.03
0.027
Terminal 70 mm²
Terminal 70 mm²
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
Terminal 35 mm²
392
285
210
16
Technical specifications
2DH33-3AA0
1GF33-3AAx
160
200
330
330
IP00
IP00
0.595
0.595
0.62
0.62
0.661
0.661
M10
M10
M10
M10
M6
M6
460
460
360
360
275
275
135
135
0.042
0.042
0.039
0.039
0.036
0.036
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
392
392
285
285
210
210
16
16
35

Advertisement

Table of Contents
loading

Table of Contents