Siemens SIMATIC Mobile Panel 277 IWLAN Application Description page 37

Evaluate through which access point the mobile panel communicates, evaluating an access point clients list
Table of Contents

Advertisement

5 Configuration Process
5.2 STEP 7 configuration
No.
Details on the configuration:
Select the (unspecified) entry under
"Connection Partner" (1)
Select "UDP connection" under
"Connection" (2) using the drop-down list
Confirm the entries using the "OK" button.
A message will be displayed. Confirm it with
"OK".
The "Properties of the UDP connection"
dialog window is opened.
Properties of the UDP connection:
"General" (1) tab:
"Local Endpoint" (2):
ID (Hex):
For the ID specify
"0001 A050".
Name:
The name can be freely selected.
In this case "UDP Access Point 1".
Note:
the ID used here and the displayed value at
the "LADDR" (3) parameter is transferred to
DB15 as "Parameter" (see
Evaluating An Access Point Clients List
V1.0, Entry ID: 48946495
Action
Link
).
Screens
(1)
(1)
(2)
(3)
(2)
37