Siemens SIMATIC Mobile Panel 277 IWLAN Application Description page 34

Evaluate through which access point the mobile panel communicates, evaluating an access point clients list
Table of Contents

Advertisement

5 Configuration Process
5.2 STEP 7 configuration
No.
2.
Properties of the mobile panel IO device:
defining the device name
Double-click to open the HMI station
properties.
In the "General" tab, you can specify the
device name.
The name you use here must be entered
in the control panel of the mobile panel in
"PROFINET".
In this example:
Device name: Mobile277FIWLANRFID
Note:
the device name can be freely selected.
For future use of the name, please note the
used notation.
(The name is case sensitive).
3.
Editing parameters of the mobile panel IO
device:
when you select the operator panel in HW
Config, the following modules are displayed:
mobile277fiwlan
Mobile277Standard_IO
Mobile277Failsafe_IO
Double-click on the individual modules to
open the respective module properties.
In this example:
mobile277fiwlan:
Mobile277Standard_IO: I address "11.0.20"
Mobile277Failsafe_IO: I address "266..275"
34
Action
Address "8184"
Q address "6..9"
Q address "266.0.273"
Screens
Evaluating An Access Point Clients List
V1.0, Entry ID: 48946495