Siemens SIMATIC Mobile Panel 277 IWLAN Application Description page 26

Evaluate through which access point the mobile panel communicates, evaluating an access point clients list
Table of Contents

Advertisement

4 Functional Mechanisms of this Application
4.2 FC220 functionality
Status messages of FC220
The status messages below are status messages that have been created
especially by the block.
Table 4-4
State
No.
1.
0000
2.
0010
3.
8000
4.
8004
5.
8303
6.
8304
7.
8403
8.
8404
9.
8101
10.
8201
11.
8102
12.
8202
26
Description
No error occurred and an object was found.
The area that is to be compared is larger than the specifications
of the input parameters.
The searched object was not found.
The data to be searched is larger than the search area.
The "SRC_STRUCT_LENGTH" input parameter is smaller than
"0".
The "SRC_STRUCT_LENGTH" input parameter is larger than
"SRC".
The "SRC_OFFSET_ERROR" input parameter is smaller than
"0".
The "SRC_OFFSET_ERROR" input parameter is larger than
"SRC".
The data type of the "COMPARE" input parameter is unknown.
The data type of the "SRC" input parameter is unknown.
The "COMPARE" input parameter shows the unauthorized data
area (V local data).
The "SRC" input parameter shows the unauthorized data area (V
local data).