Report the version of firmware running in the PP420
11.2
Lighting commands
Set the SafeSense mode
Set the output current rating
Set continuous mode
Set switched mode
VR
This command returns the firmware version. For example:
PP420 (HW001) V029
REc,m
Where:
c
output channel (1 to 4)
m
SafeSense mode:
Bit 0 =
0: S flag set (prompt for current rating enabled)
1: S flag cleared (prompt for current rating disabled)
Bit 1 =
0: E flag set (error detection enabled)
1: E flag cleared (error detection disabled)
Bit 2 =
0: P flag set (positive triggers)
1: P flag cleared (negative triggers)
This command changes the current rating for a light:
RRv,c
Where:
output channel (1 to 4)
c
v
rated current (10mA to 2A)
The output is set to continuous mode at a percentage of full
brightness:
RSc,s
Where:
c
output channel (1 to 4)
s
setting in percent (0 to 100)
The output is set to continuous mode at a percentage of full
brightness:
RWc,s
—
31
PP420 LED lighting controllers - User Manual
—