Festo CPV GE-ASI Series Brief Description page 11

Valve terminal with as-interface
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
1
User
instructionsEnglish
The AS-Interface valve terminal type 10 is designed exclus-
ively for controlling pneumatic actuators and may only be
used in bus systems as agreed in the AS-Interface specifi-
cations. The specified limit values for pressures, tempera-
tures, electrical data, torques etc. must be observed.
AS-Interface bus systems and valve terminals may only be
installed by specially qualified personnel. Detailed specifi-
cations on the concept and addressing of the AS-Interface
bus system can be found in the manual for the master.
Detailed information on the pneumatic components of the
valve terminal can be found in the pneumatics manual
P.BE-CPV-....
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Connect an earth conductor of sufficient cross-sec-
tional area to the terminal marked with the earth
symbol.
S Commission only a valve terminal which has been
fitted and wired completely.
If to be used as an explosion-protected operating de-
vice, make sure that:
S electrical contacts are not disconnected under ten-
sion
S the completely fitted valve terminal with all plugs,
adapters and protective caps complies at least with
protection class IP 64.
Festo CPV..-GE-ASI-... 0112b English
11