C-BOX 400/410
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic C-BOX 400

  • Page 1 C-BOX 400/410 Installation Manual...
  • Page 3 C-BOX 400/410 INSTALLATION MANUAL...
  • Page 4 Datalogic S.p.A. reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Page 5: Table Of Contents

    CONTENTS GUIDE TO INSTALLATION ................ iv GENERAL VIEW ..................v SAFETY PRECAUTIONS................ix Power Supply....................ix Safety Notes ....................ix WEEE Compliance ..................x GENERAL FEATURES ................1 Description ....................1 1.1.1 DeviceNet ..................... 2 INSTALLATION.................... 3 Package Contents..................3 Opening the Device ..................4 Mechanical Installation..................
  • Page 6: Guide To Installation

    GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the C-BOX 4X0. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Correctly position and mount the C-BOX 4X0 within the reach of the barcode scanner cable, according to the information in paragraph 2.3.
  • Page 7: General View

    GENERAL VIEW C-BOX 400 Figure A 25-pin scanner connector Shield Nut Compression Connectors DeviceNet Connector Cover screws (4)
  • Page 8 C-BOX 410 Figure B LCD display Keypad...
  • Page 9 C-BOX 400/410 Figure C - Cover Inside LCD contrast trimmer Configuration switch Power on (PWR) LED Node address selectors Baud rate selector Transmission (TX) LED Module status (MS) LEDs Warning (WL) LED Network status (NS) LEDs...
  • Page 10 C-BOX 400/410 Figure E - Bottom Inside Power on switch SEND button Scanner chassis grounding selector Auxiliary port connector OM4000 jumpers Spring clamp terminal blocks Warning LED GET button Power polarity error LED TEST button viii...
  • Page 11: Safety Precautions

    SAFETY PRECAUTIONS POWER SUPPLY ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT - This product is intended to be installed by Qualified Personnel only. The C-BOX 4X0 is intended to be supplied either by a UL Listed NEC Class 2 power source, or a UL Listed ITE Limited Power Source (LPS), rated 10-30 V dc, minimum 0.5 A.
  • Page 12: Weee Compliance

    Terminating Resistors Two 121 Ohm, 1% Metal Film, ¼ Watt terminating resistors should be installed at each side of the DeviceNet trunk line (not at the end of a drop line or in a node). If the bus is incorrectly terminated, this can lead to errors in data transfer failure.
  • Page 13: General Features

    In the C-BOX 410, visualize the data packet sent by the scanner on the LCD. The C-BOX 400 / C-BOX 410 mechanical dimensions are 167 x 115 x 61 mm (6.57 x 4.53 x 2.40 in.). The C-BOX 400 weighs about 470 g (16.50 oz); the C-BOX 410 weighs about 530 g (18.70 oz).
  • Page 14: Devicenet

    C-BOX 400/410 A dedicated shield nut offers the possibility to further increase the C-BOX 4X0 noise immunity by simply connecting the ground. The fixing screw type is 4-40 UNC, 1/8 inch. 1.1.1 DeviceNet DeviceNet is a low level network that provides connections between simple industrial devices (sensors, actuators) and higher level devices (controllers), and eliminates expensive hardwiring.
  • Page 15: Installation

    INSTALLATION 2 INSTALLATION PACKAGE CONTENTS Verify that the C-BOX 4X0 and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: C-BOX 4X0 Installation manual C-BOX 4X0 configuration CD-ROM 2 mounting screws Figure 1 - C-BOX 4X0 Package Contents...
  • Page 16: Opening The Device

    C-BOX 400/410 OPENING THE DEVICE To install the C-BOX 4X0 or during normal maintenance, it is necessary to open it by unscrewing the four cover screws: The C-BOX 4X0 must be disconnected from the power supply during this operation. CAUTION...
  • Page 17: Mechanical Installation

    INSTALLATION MECHANICAL INSTALLATION The diagram below gives the overall dimensions of the C-BOX 4X0 and may be used for its installation. Figure 3 - Overall Dimensions...
  • Page 18 C-BOX 400/410 C-BOX 4X0 can be installed to operate in different positions. The two screw holes inside the housing of the C-BOX 4X0 are for mechanical fixture (Figure 4). To mount the C-BOX 4X0: Open the C-BOX 4X0 by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the device as a pattern, mark the panel with an appropriate object and then drill two holes in the panel.
  • Page 19: Electrical Connections And Setup

    INSTALLATION ELECTRICAL CONNECTIONS AND SETUP The following figure shows the typical layout. DeviceNet MASTER C-BOX 4X0 SCANNER System Cables Figure 5 – System Layout Matrix readers are not compatible with the WinHost configuration program. For Matrix reader setup first read par. 2.9 for details. NOTE A PC can be connected to the C-BOX 4X0 (and consequently to the scanner auxiliary interface) through the internal 9-pin connector.
  • Page 20: Power Supply

    C-BOX 400/410 Autoconnection is not compatible with Matrix readers and must be disabled in the C-BOX 4x0 configuration. See par. 2.9 for details. NOTE To disable this automatic connection procedure, refer to WinHost Help Online. After system functioning has been verified, close the C-BOX 4X0 using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing.
  • Page 21 INSTALLATION Pin 1 is also electrically connected to pins 3 and 5, just as pin 2 is electrically connected to pins 4 and 6. This is useful for external trigger/inputs connections. NOTE Incorrect grounding of the C-BOX 4X0 can injure personnel and damage equipment.
  • Page 22: System Wiring

    C-BOX 400/410 2.4.2 System Wiring The connection and wiring procedure for C-BOX 4X0 is described as follows: Open the C-BOX 4X0 as described in paragraph 2.2. Verify that the C-BOX 4X0 power switch is off (see Figure 6). Unscrew the compression connectors and pass all the system cables through them into the C-BOX 4X0 housing.
  • Page 23 INSTALLATION The C-BOX 4X0 spring clamp connector pinouts are indicated in the following table. Refer to the scanner Installation Manual for details. Name 1, 3, 5 2, 4, 6 7, 8 EARTH GROUND 9…12, 20, 33, 34, 40 Reserved DS2100A DS4600A Matrix-2000™...
  • Page 24: Scanner Chassis Grounding Jumper Settings

    C-BOX 400/410 2.4.3 Scanner Chassis Grounding Jumper Settings The scanner chassis grounding method can be selected by positioning a jumper (see Figure 9). In this way the scanner chassis can be connected to earth ground (only if pins 7 or 8 are connected to a good earth ground) or to the power supply ground signal.
  • Page 25: Devicenet Connections And Setup

    INSTALLATION DEVICENET CONNECTIONS AND SETUP 2.5.1 DeviceNet Node Address (MAC ID) and Baud Rate Selection To interface the C-BOX 4X0 with a DeviceNet network, the Node Address (MAC ID) and the baud rate should be set using the rotary switches placed in the cover inside. The valid address range for the Node Address (MAC ID) is from 00 to 63.
  • Page 26: Connection To A Devicenet Network

    C-BOX 400/410 M12 external male connector pinout Pin Name Function Shield/Drain Shield Bus power supply Bus reference CAN_H CAN bus data line - H CAN_L CAN bus data line - L 2.5.3 Connection to a DeviceNet Network The following figure shows a DeviceNet layout with C-BOX 4X0 devices connected to...
  • Page 27: C-Box 4X0 Configuration For Devicenet Slave Node

    DeviceNet network application as described in the configurator's Help On- Line or User's Manual. Further information on DeviceNet protocol and Flow control is provided in the C-BOX 400/410 DeviceNet document and Help On- Line installed from the configuration CD-ROM provided in the C-BOX package.
  • Page 28: Configuration Switch And 9-Pin Internal Connector

    C-BOX 400/410 CONFIGURATION SWITCH AND 9-PIN INTERNAL CONNECTOR The 9-pin internal connector may have two different functions according to the position of the configuration switch. Figure 13 - Configuration Switch and 9-pin Male Connector POSITION MODE Normal Operation (default): In this position, the C-BOX 4X0 is in the normal operating mode.
  • Page 29 INSTALLATION POSITION MODE CFG: When the switch is in this position, the C-BOX 4X0 is in configuration mode. The communication with the scanner is interrupted and pins 2 and 3 are no longer dedicated to the scanner auxiliary interface but to the C-BOX 4X0 configuration (see table below). The system enters configuration mode and waits to be configured through WinHost (see WinHost Help On Line).
  • Page 30: Barcode Scanner Requirements

    OFF), the C-BOX 4X0 is ready to receive code strings from the barcode scanner's RS232 main interface. Then, it converts them to the DeviceNet network. GET/TEST/SEND: Through the C-BOX 400 internal buttons and the C-BOX 410 external keypad, it is possible to communicate with the barcode scanner to perform one of the following functions: •...
  • Page 31: Get/Test/Send Functions

    INSTALLATION 2.8.1 GET/TEST/SEND Functions The C-BOX 4X0 has three internal function buttons. In the C-BOX 410, these three buttons are also available on the cover and their function is indicated on the display. C-BOX 4X0 TEST SEND C-BOX 410 Figure 14 – Internal Function Buttons The GET/TEST/SEND function is not compatible with Matrix readers.
  • Page 32 Once the buttons are released in step 1, a ten-second timeout starts. If no button is pressed within this time (no function is selected), the procedure will be cancelled. The C-BOX 400 warning LED (Figure 17) is turned OFF at the end of each procedure. NOTE The C-BOX 410 display visualizes self-explaining messages about GET/TEST/SEND functions.
  • Page 33: Led Indicators

    LED Indicators TX Led Power on MS Leds NS Leds Warning LED Figure 15 - LED Indicators In the C-BOX 400 the Warning LED is repeated in the bottom inside. Warning Power Polarity Error LED Figure 16 - C-BOX 400...
  • Page 34 ON. (red) indicates a warning or error condition. It is ON when the WARNING Auto-Connection procedure with a Datalogic reader is in progress (the system is busy), during a GET/TEST/SEND procedure or during the Configuration Mode. It blinks when an error condition occurs.
  • Page 35: Special Notes For Matrix Reader Setup

    INSTALLATION (red) indicates a wrong polarity. While activated, all other POWER POLARITY ERROR LEDs will be off until the power feed is connected with correct polarity. SPECIAL NOTES FOR MATRIX READER SETUP When connected to a C-BOX 4x0 through the 25-pin connector, the 9-pin Auxiliary port connector on the Matrix reader cannot be used for communication (i.e.
  • Page 36: Matrix Reader Configuration Using Visiset

    C-BOX 400/410 Figure 17 – WinHost Configuration Menu for C-Box 4x0 Return the Configuration Switch to the Normal Operation position. 2.9.2 Matrix Reader Configuration Using VisiSet™ After performing C-Box 4x0 configuration as described in the previous paragraph, the Matrix reader can be configured through the C-Box 4x0 9-pin internal connector connected to the PC using the VisiSet™...
  • Page 37: Completing C-Box 4X0 Configuration For Matrix-1000™ Readers

    INSTALLATION 2.9.3 Completing C-Box 4x0 Configuration for Matrix-1000™ Readers When connected to a C-BOX 4x0/4x0, Matrix-1000™ can only communicate through its Auxiliary Interface. CAUTION Once Matrix-1000™ has been configured through VisiSet™ as described in the previous paragraph, to complete the configuration procedure the C-Box 4x0 must be reconfigured to accept data from the Matrix-1000™...
  • Page 38: Technical Features

    C-BOX 400/410 3 TECHNICAL FEATURES ELECTRICAL FEATURES C-BOX 400 C-BOX 410 Power Supply voltage 10 to 30 Vdc Power consumption max. 2.3 W + scanner 3.8 W + scanner USER INTERFACE LED indicators Power ON, Warning, PHYSICAL FEATURES Mechanical dimensions 167 x 115 x 61 mm (6.57 x 4.53 x 2.40 in.)
  • Page 39 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX-4X0 e tutti i suoi modelli and all its models et tous ses modèles...