Power Supply - Datalogic C-BOX 400 Installation Manual

Table of Contents

Advertisement

2
Autoconnection is not compatible with Matrix readers and must be
disabled in the C-BOX 4x0 configuration. See par. 2.9 for details.
NOTE
To disable this automatic connection procedure, refer to WinHost Help Online.
After system functioning has been verified, close the C-BOX 4X0 using the 4 cover
screws making sure the rubber seal is fitted correctly between the parts of the
housing.
2.4.1

Power Supply

Power is supplied to the C-BOX 4X0 through the pins provided on the spring clamp
connector.
The power switch (see Figure 6) switches the power supply ON or OFF for both the
C-BOX 4X0 and the connected scanner.
C-BOX
The power supply must be between 10 and 30 Vdc only.
8
Figure 6 - Power Switch ON/OFF Positions
1
VS
GND
2
Figure 7 - Power Supply Connections
ON
S1
OFF
USER INTERFACE
V+ (10 - 30 Vdc)
GND
C-BOX 400/410