INSTALLATION
2.9.3
Completing C-Box 4x0 Configuration for Matrix-1000™
Readers
When connected to a C-BOX 4x0/4x0, Matrix-1000™ can only
communicate through its Auxiliary Interface.
CAUTION
Once Matrix-1000™ has been configured through VisiSet™ as described in the
previous paragraph, to complete the configuration procedure the C-Box 4x0 must be
reconfigured to accept data from the Matrix-1000™ reader through its Auxiliary
RS232 interface (the only RS232 interface available).
1.
Move the C-Box 4x0 Configuration Switch from the Normal Operation to the
CFG position;
2.
Connect the 9-pin internal port of the C-BOX 4x0 to the PC (using a crossover
cable) and run the Winhost™ configuration tool;
3.
Select the Connect option to open communications with the C-BOX 4x0 and
wait until the correct communication speed has been determined;
4.
From the SCANNER INTERFACE menu, set Data Source: Aux Interface and
save the configuration to the C-Box 4x0 (refer to Figure 18);
5.
Return the Configuration Switch to the Normal Operation position;
Figure 18 – WinHost Configuration Menu for C-Box 4x0
6.
Close the C-BOX 300.