Download Print this page

Datalogic BM100 Instruction Manual

Backup module

Advertisement

Quick Links

BM100
BACKUP MODULE
INSTRUCTION MANUAL
6
5
4
3
Figure 1 General View
Backup/Restore button
Network Address Switches
1
5
Backup/Restore Indicator LEDs
2
BM150 Display connector
6
Network Type Switch
Write Protection Lock
7
3
ID-NET™ Baudrate Switch
4
DESCRIPTION
The BM100 Backup Module is an accessory for the CBX series
connection boxes. It provides the following functions:
Backup and Restore
Complete Configuration and Environmental parameter storage
for network and reading devices. Includes write protection.
Network Address Selection
Hardware Address selection for Fieldbus or ID-NET™ Slave
devices (overrides software configuration).
Network Type Selection
Selection of Fieldbus or ID-NET™ Slave type networking
depending on application and installed accessories.
BM150 Accessory Display Connection (CBX500 only)
Connection to flat cable for BM150 Display and Keypad.
821001400
INSTALLATION
CAUTION
The BM100 can easily be installed into the CBX100 or CBX500
connection box by aligning it over its corresponding connector and
pushing down until correctly seated. When closed, the plastic
7
1
support inside the CBX cover holds the module in place.
2
Power must be off during this operation.
Figure 2 – BM100 Mounting
BACKUP AND RESTORE PROCEDURE
The backup and restore functions are valid for any application
layout type (point-to-point, network, etc.) using either CBX100 or
CBX500 connection boxes.
If it ever becomes necessary to replace the reading device it can
be quickly configured through the restore procedure.
BM100 always provides complete backup and restore functions
(Configuration and Environmental parameters) and cannot be
interrupted once started (LED quickly blinking).
For Network nodes, the backup module of the Master saves
the configuration of all the reading devices in the network,
Master and all individual Slaves.
For single reading device stations or for Slaves, the backup
module saves the configuration of the specific connected
reading device.
These functions are cyclical every 3 seconds:
Backup
Restore
No Action
To perform Backup:
1. Make sure the Write Protection switch is unlocked.
2. Press and hold the Backup & Restore button for approximately
3 seconds. The green Backup LED (B) lights up.
3. Release the button. The green Backup LED (B) blinks slowly.
4. Press the Backup & Restore button again while the LED is
blinking. The green Backup LED (B) blinks quickly indicating
the backup procedure is active. When the LED turns off the
procedure is complete.
5. Set the Write Protection switch to locked.
To perform Restore:
1. Press and hold the Backup & Restore button for approximately
6 seconds. The yellow Restore LED (R) lights up.
2. Release the button. The yellow Restore LED (R) blinks slowly.
3. Press the Backup & Restore button again while the LED is
blinking. The yellow Restore LED (R) blinks quickly indicating
the restore procedure is active. When the LED turns off the
procedure is complete.
To exit without performing Backup or Restore procedures, release
the button while both LEDs are off (No Action), or wait for about 3
seconds (timeout) after the slow blinking LED.

Advertisement

loading

Summary of Contents for Datalogic BM100

  • Page 1 CAUTION be quickly configured through the restore procedure. INSTRUCTION MANUAL The BM100 can easily be installed into the CBX100 or CBX500 BM100 always provides complete backup and restore functions connection box by aligning it over its corresponding connector and (Configuration and Environmental parameters) and cannot be pushing down until correctly seated.