3

3 TECHNICAL FEATURES

ELECTRICAL FEATURES
Power
Supply voltage
Power consumption max.
USER INTERFACE
LED indicators
PHYSICAL FEATURES
Mechanical dimensions
Weight
SOFTWARE FEATURES
Parameter storage
DEVICENET INTERFACE
Interface type
Data transfer rate
ENVIRONMENTAL FEATURES
Operating temperature
Storage temperature
Humidity max.
Vibration resistance
IEC 68-2-6 test FC
Shock resistance
IEC 68-2-27 test EA
Protection class
The features given are typical at a 25
not otherwise indicated).
NOTE
26
C-BOX 400
10 to 30 Vdc
2.3 W + scanner
Power ON, Warning,
167 x 115 x 61 mm (6.57 x 4.53 x 2.40 in.)
about 470 g. (16.50 oz.)
Non-volatile internal memory
Kbit/s 125, 250, 500 (user selectable)
-10° to 50 °C (+14° to 122 °F)
-20° to 70 °C (-4° to 158 °F)
90% non condensing
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2g @ 70 to 200 Hz; 2 hours on each axis
30g; 11 ms;
3 shocks on each axis
(when correctly connected to the scanner)
°
C ambient temperature (if
C-BOX 400/410
C-BOX 410
3.8 W + scanner
Tx
about 530 g. (18.70 oz.)
CAN
IP64