Inlet Valve
6 - Replace the sediment filter at
the water softener inlet. Close the
supply valve at the water softener
inlet. Relieve the pressure in the
filter by loosening the bleed screw
and close it again. Unscrew the
body nut located in the lower part
of the filter in the direction of the
screw, discard the filter inside and
insert a new one and tighten the
body nut. Open the inlet valve
again.
Bleeder Screw
(Purger)
7 - Clean the trap group dirt catcher. It should be
checked when the pressure is zero and the device is
cold. The condensate tank is cleaned in the same
way as the strainer.
All equipment in the external body of the steam
generator, main body, burner, pump, etc. parts need
to be cleaned.
Body Nut
53