h – Feed Water Characteristics
✓Considering a lime furring of 1 mm. thickness causes a 7% fuel loss; for a long-lasting and
efficient operation of your Steam Generator, feed water input hardness value should be 0˚Fr
hardness.
ANALYZES
T. HARDNESS
Fr
0
P – ALKALI
ppm
pH
CONDUCTIVITY
Us/cm
CHLORIDE
ppm
A. PHOSPHONATE
CF
SOFT WATER
(Collected Sample)
CONDENSATE
(Collected Sample)
BOILER
BOILER LIMITS
(Collected
Sample)
0 - 1
< 1300
10,5 - 12
< 1000
< 500
10 – 15
6 - 12
21