PROBLEM
DESCRIPTION
Fault Nb. 1
High Pressure
High Vapor
Fault Nb. 2
Temperature
High Smokestack
Fault Nb. 3
Temperature
Inverter
Fault Nb. 5
Malfunction
Pressurization
Fault Nb. 6
Pump Malfunction
Fault Nb. 7
Burner Malfunction
Fault Nb. 8
No feed water.
Speck Pump
Fault Nb. 0
Thermic
Malfunction
POSSIBLE REASON
Indicates that the specified operation
pressure is exceeded.
Buhar sıcaklığının set değerinin
üzerine çıktığını gösterir.
Baca sıcaklığının set değerinin
üzerine çıktığını gösterir.
Indicates the inverter is signaling
an error and no power to the
pump.
Indicates that the thermal of the
pressurization pump inside the
electrical control panel is waste.
Indicates that the burner is not
operating regularly.
Means no water can be supplied to
the steam generator.
Indicates that the speck pump
motor thermal inside the electrical
control panel is waste.
SOLUTION
Check whether the safety switch is set to a higher pressure
than the operation switch.
The thermostat setpoint, pump flow, condensate tank water
level and pump strainer must be checked. This means that the
system cannot supply enough water and the device has
passed into superheated steam. If the temperature of the
condensate tank water rises above 70, it must be lowered.
Strictly, the first filling must be done manually, after
the water has come out of the first start valve.
The thermostat setpoint must be checked. The burner settings
should be reviewed and the capacity reduced if necessary.
First filling must be performed manually after it is seen
that water is coming from the first operation valve.
See the inverter error codes in the operating instructions
folder.
Check the electrical voltage to the pressurization pump. Check
the thermal setting.
It is necessary to check whether the pump pumps the water in
the condensate tank, the amount of water in the condensate
tank, the connections of the water flow controller on the feed
water installation.
It is necessary to check whether the pump pumps the water in
the condensate tank, the amount of water in the condensate
tank, the connections of the water flow controller on the feed
water installation.
Check the electrical voltage to the Speck pump motor. Check
the thermal setting. (2 pumps)